Warning! When the appliance is in use
and depending on the programme
selected there can be hot water in the
pump. Never remove the pump cover
during a wash cycle, always wait until the
appliance has finished the cycle, and is
empty. When refitting the pump cover ,
ensure it is securely re-tightened so as
to stop leaks and young children being
able to remove it.
Cleaning the water inlet filters
If you notice that the machine is taking longer
to fill, check that the filter in the water inlet
hose is not blocked.
1. Turn off the water tap.
2. Unscrew the water inlet hose.
3. Clean the filter in the hose using a hard
bristle brush.
4. Screw the hose back onto the tap.
5. Unscrew the hose from the machine.
Keep a rug nearby because some water
may flow.
6. Clean the filter in the valve with a stiff
brush or with the piece of cloth.
7. Screw the hose back to the machine and
make sure the connection is tight.
8. Turn on the water tap.
Emergency emptying out
If the water is not discharged, proceed as
follows to empty out the machine:
1. pull out the plug from the power socket;
2. close the water tap;
3. if necessary, wait until the water has
cooled down;
4. open the pump door;
5. place a bowl on the floor. Remove the
emergency emptying cap from the filter.
The water should drain by gravity into the
bowl. When the bowl is full, refit the cap
into the filter. Empty the bowl. Repeat the
procedure until water stops flowing out;
6. clean the pump if necessary as previously
described;
7. screw the pump again and close the
door.
Frost precautions
If the machine is installed in a place where the
temperature could drop below 0°C, proceed
as follows:
1. Pull out the plug from the power socket.
2. Turn off the water tap.
3. Unscrew the inlet hose.
4. Place the end of the inlet hose in a bowl
placed on the floor, open the emergency
emptying cup of the filter and let water
drain out.
5. Refit the emergency emptying cap into
the filter and screw the water inlet hose
back.
electrolux 19