beautypg.com

Gas freestanding ranges, Side, Front – Electrolux EW3LGF65G B User Manual

Page 2

background image

Gas Freestanding Ranges

EW3LGF65G S, EW3LGF65G W, EW3LGF65G B

High standards of quality at Electrolux Major Appliances mean we are

constantly working to improve our products. We reserve the right to change

specifications or discontinue models without notice.

USA

250 Bobby Jones Expressway

Augusta, GA 30907

1-877-4electrolux (1-877-435-3287)

electroluxappliances.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxappliances.ca

EW3LGF65G 01/08

© 2008 Electrolux Major Appliances, NA

Printed in the U.S.A.

Side

Overall depth

including oven

door in 90

°

open

position – 47"

28

5

/

8

"

26

3

/

8

"

Front

35

7

/

8

"

Adjustable

to

36

1

/

8

"

29

7

/

8

"

11

5

/

8

"

47

1

/

2

"

30" min.

13"

max.

25"

24"

5" min.
to nearest
combustible
wall (either
side of unit)
above 36"
height

30

1

/

8

"

2"

15"

11

1

/

2

"

Area allows for flush

installation with through-

the-floor connection

of pipe stub/shutoff valve

Area allows for flush

installation with through-

the-wall connection of

pipe stub/shutoff valve

and rear wall 120V outlet

CL

10

1

/

2

"

7"

23"

18" min.

36"

stand.

34"

min.

Gas

connection

and power

supply

location

(right bottom

rear)

30" Gas Freestanding Range Specifications

Product Weight – 260 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.8 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)

Amps @ 120 Volts = 15 Amps

Always consult local and /or national electric and gas codes.

Range ships with 3/4" factory regulator.

Range is Lp only and cannot be converted to natural gas.

Overhead cabinetry should not exceed a 13" maximum depth.

Allow 30" minimum clearance between top of rangetop and bottom of
unprotected wood or metal overhead cabinetry.

Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.

Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.

Allow 5" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.

To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories

Wok Ring – (318254307).

Simmer Plate – (318254206).

This manual is related to the following products: