Gas freestanding ranges, Side, Front – Electrolux EW3LGF65G B User Manual
Page 2
Gas Freestanding Ranges
EW3LGF65G S, EW3LGF65G W, EW3LGF65G B
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
•
250 Bobby Jones Expressway
•
Augusta, GA 30907
•
1-877-4electrolux (1-877-435-3287)
•
electroluxappliances.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
electroluxappliances.ca
EW3LGF65G 01/08
© 2008 Electrolux Major Appliances, NA
Printed in the U.S.A.
Side
Overall depth
including oven
door in 90
°
open
position – 47"
28
5
/
8
"
26
3
/
8
"
Front
35
7
/
8
"
Adjustable
to
36
1
/
8
"
29
7
/
8
"
11
5
/
8
"
47
1
/
2
"
30" min.
13"
max.
25"
24"
5" min.
to nearest
combustible
wall (either
side of unit)
above 36"
height
30
1
/
8
"
2"
15"
11
1
/
2
"
Area allows for flush
installation with through-
the-floor connection
of pipe stub/shutoff valve
Area allows for flush
installation with through-
the-wall connection of
pipe stub/shutoff valve
and rear wall 120V outlet
CL
10
1
/
2
"
7"
23"
18" min.
36"
stand.
34"
min.
Gas
connection
and power
supply
location
(right bottom
rear)
30" Gas Freestanding Range Specifications
•
Product Weight – 260 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.8 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 15 Amps
•
Always consult local and /or national electric and gas codes.
•
Range ships with 3/4" factory regulator.
•
Range is Lp only and cannot be converted to natural gas.
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Allow 30" minimum clearance between top of rangetop and bottom of
unprotected wood or metal overhead cabinetry.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
•
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
•
Allow 5" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.
•
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
•
Wok Ring – (318254307).
•
Simmer Plate – (318254206).