Repairs, Environmental protection, Technical specifications – Elektra Beckum Compressor Pump Basic 265 User Manual
Page 6: English
10
ENGLISH
•
Hose connection between compres-
sor and air tool leaky.
−
Check air hoses, replace defec-
tive parts if necessary.
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Power tools in need of repair can be sent
to one of the adresses listed on the sec-
ond-last page.
Please attach a description of the fault to
the power tool.
The machine’s packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
7.
Repairs
8.
Environmental Protection
9.
Technical Specifications
Suction capacity
l/min
235
Free air delivery (volume flow rate)
l/min
125
Filling rate
l/min
145
Working pressure (compression end pressure)
bar
8
Pressure vessel volume
l
50
No. of air outlets
2
Pump model
F 245
No. of cylinders
1
Motor speed
min
-1
2850
Motor capacity
W
1.5
Supply voltage (50 Hz)
V
230
Rated current
A
6.8
Fuse protection min.
A
10 (time-lag)
Degree of protection
IP 20
Max. overall cable length when using extension cables:
– at 3 x 1.0 mm
2
lead cross section
– at 3 x 1.5 mm
2
lead cross section
– at 3 x 2.5 mm
2
lead cross section
m
m
m
10
25
25
Dimensions length x width x height
mm
905 x 410 x 690
Weight
kg
25
Sound pressure level at 1 m max.
dB (A)
88 ± 3