beautypg.com

Felectrical connections, Permanent connection, Fitting the hob into the worktop – Electrolux EHG 691 User Manual

Page 10: Supply cable replacement

background image

10

Permanent Connection

In the case of a permanent connection, it is necessary

that you install a double pole switch between the hob

and the electricity supply (mains), with a minimum gap

of 3 mm. between the switch contacts and of a type

suitable for the required load in compliance with the current

electric regulations.
The switch must not break the yellow and green earth

cable at any point.

Ensure that the hob supply cord does not come

into contact with surfaces with temperatures

higher than 50 deg. C.

FO 0390

F

Electrical connections

Any electrical work required to install this hob

should be carried out by a qualified electrician or

competent person, in accordance with the current

regulations.

THIS HOB MUST BE EARTHED.

The manufacturer declines any liability should these

safety measures not be observed.

This hob is designed to be connected to a 230-240V

50Hz AC electrical supply.
Before switching on, make sure the electricity supply

voltage is the same as that indicated on the hob rating

plate. The rating plate is located on the bottom of the

hob. A copy is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cord

incorporating a 3amp plug fitted. In the event of having to

change the fuse, a 3amp ASTA approved (BS 1362) fuse

must be used.
Should the plug need to be replaced for any reason, the

wires in the mains lead are coloured in accordance with

the following code:
Green and Yellow - Earth
Blue

- Neutral

Brown

- Live

— Connect the green and yellow (earth) wire to

the terminal in the plug which is marked with
the letter 'E' or the earth symbol or coloured

green and yellow.

— Connect the blue (neutral) wire to the terminal

in the plug which is marked with the letter 'N' or

coloured black.

— Connect the brown (live) wire to the terminal in

the plug which is marked with the letter 'L' or

coloured red.

Upon completion there must be no cut, or stray strands

of wire present and the cord clamp must be secure over

the outer sheath.

A cut off plug inserted into a 13 amp socket is

a serious safety (shock) hazard. Ensure that

the cut off plug is disposed of safely.

FO 0199

a

Fitting the Hob into the worktop

Carry out the building in of the hob as follows:

• put the seals supplied with the hob, on the

edges of the cut out taking care that the seals

meet without overlapping;

• place the hob in the cut out, taking care that it

is centred;

• fix the hob with the relevant fixing clamps and

screws, as shown in the diagram. When the

screws have been tightened, the excess seal

can be removed.

The edge of the hob forms a double seal which prevents

the ingress of liquids.

a) Sealing gasket

F

Min. size Cable/flex Cable / flex type

Fuse

0.75 mm

2

H05 V2V2-F (T90)

3 A

Supply cable replacement

The cable used to connect the hob to the electrical supply

must comply to the specifications given below.