80 Series

®

Universal Thermostats

White-Rodgers

WR-2278-2

St. Louis, Missouri Markham, Ontario

314-553-3600

905-201-4701

www.white-rodgers.com

1F85-275

Multi-Stage/Heat Pump/Single Stage

5/1/1 Day Programmable

or Non-Programmable

1F85-277

Multi-Stage/Heat Pump/Single Stage

7 Day, 5/1/1 Day Programmable

or Non-Programmable

1F83-277

Multi-Stage/Heat Pump/Single Stage

Non-Programmable

Programming (1F85-277)/(1F85-275)

Choice of 7 day or 5/1/1 day
programmable or non-programmable

4 time and 4 temperature settings per
program (heat & cool)

Energy savings up to 33%

Patented pre-programmed software
simplifies time and temperature
programming

Display

40% larger LCD with improved contrast for
easier reading

Lighted display for easier low-light viewing

Performance

Universal – Single Stage, Multi-Stage
or Heat Pump

Dual Powered (Hardwire and Battery)
(Patented)

Coded keypad lockout

Selectable Energy Management Recovery
(1F85-275)/(1F85-277)

Meets ENERGY STAR

®

specifications

(1F85-275)/(1F85-277)

Meets California Building Code, Title 24
(1F85-275)/(1F85-277)

Fast (FA) or slow (SL) heating cycle anticipation

Compressor lockout protection (optional)

Setpoint temperature limits

Comfort & Convenience

Optional minimum and maximum
temperature configurable

Auto Changeover (optional)

Permanent program retention during
power loss, no batteries needed

Indefinite setpoint Hold

Air filter change indicator

Simple “set-up” menu to activate
optional features

Programmed temporary temperature
override 4 hours max.

Maintains room temperature differential
within +/- 1°

Display temperature recalibration (+/- 4°)

Includes 2 “AA” alkaline batteries for long
battery life

Dimensions

6.1"H x 3.8"W x 1.1"D

Electrical Specifications

Rating
20 to 30 VAC, 50/60 Hz or DC

0.05 to 1.0 Amp (load per terminal)

2.5 Amps maximum load (all terminals combined)

Standard Systems
Multi-Stage—2 stage heat, 2 stage cool

Heat Pump—2 or 3 stage heat, 1 stage cool

Single stage gas, oil, electric

Thermal Specifications

Setpoint Temperature Range:
45° to 90°F (7° to 32°C)

Rated Differential:
0.6° to 1.6°F with adjustable anticipation

Operating Ambient Temperature:
32° to 105°F (0° to 40°C)

Operating Humidity Range:
90% non-condensing maximum

Shipping Temperature Range:
-4° to 150°F (-20° to 65°C)

Accessories

Wall Plate F61-2500 (7.6"W x 4.8"H)

Thermostat Guard F29-0231

(For additional guard options refer
to White-Rodgers catalog)

For Additional Information

Visit www.white-rodgers.com

C

G

W2

Y2

Y1

O

B

L

E/W1

R

Heat

Relay

(Stg. 2)

24V Hot

Heat

Relay

(Stg. 1)

Cool

Relay

(Stg. 1)

Cool

Relay

(Stg. 2)

24V

Common

(Optional)

Energized

in Cool

Energized

in Heat

System

Monitor

Blower/Fan

Terminal Designations

• Auto-Changeover • 7 Day, 5/1/1 Day Programmable or Non-Programmable • Hardwired or Battery Powered

Programs

Program

Options

Programmable

Fan

Energy

Star

Diplay

Size

(sq. in.)

Cool

Savings

Warranty

(Years)

Model

Number

Model

Gas/Oil/

Electric

3 Wire

Zone

Valve

Thermostat

Power

Source*

Millivolt

Compatible

Applications

Selectable Performance Features

Comfort & Convenience Features

Stages Heat/Cool

by System

Single

Stage

Multi-
Stage

Heat

Pump

Auto

Changeover

Memory
Back-up

P-Permanent

B-Battery

Lighted

Display

Energy

Management

Recovery

Alkaline

Battery Life

(Years)

Furnace Lockout

Ignition

Module Reset

2/1

2/1

2/1

2/2

2/2

2/2

1/1

1/1

1/1

1F85-277

1F85-275

1F83-277

7, 5+1+1, Ш

5+1+1, Ш

Ш

H/B

H/B

H/B

2.2

2.2

2.2

2+

2+

2+

P

P

P

1

1

1

Program
Override

* H/B= Hardwired or Battery option