beautypg.com

Electrical connection – Electrolux pmn User Manual

Page 19

background image

Installation Instructions

39

Electrical Connection

• The mains connection terminals are on the underside of the appli-

ance, behind a cover. The hob is to be connected in accordance with
the connection diagram as a function of the mains supply present...

• The earth conductor is connected to the

terminal, the earth wire

must be longer than the current carrying wires. If necessary, the
bridges on the terminal block must be changed as appropriate.

• The cable connections must be made in accordance with regula-

tions and the terminal screws fully tightened.

• The connecting cable is then to be secured using the strain relief

clamp.

1

• Following connection to the mains supply, all cooking zones are to be

switched on, at the maximum setting, one after the other for approx.
30 seconds to check that they function correctly.

Connection Diagram 230 V

~

230 V~

2 N~

1

2

3

4

5

230 V~

L1

N

PE

1

2

3

4

5

230 V~

230 V~

L2

L1

N

PE