4 Installation and Connection

34

Table 4: Electrical

values for external

powering of LED

ring

4.5.2 Tabletop

Installation,

Connection

Note:

• Audio

Connection

• Connecting to a

Bodypack T

Trans-

mitter

1. Unsolder the black wire (LED +) and the outer shield

(LED -) from the DPA phantom power adapter.

2. Connect the black wire (LED +) and the outer shield

(LED -) to a voltage source with an output voltage as
per Table 4:

1. Drill an 11-mm (7/16") hole through the tabletop.
2. Thread the connecting cable of the Installation Mod-

ule through the opening and the supplied fixing screw.

3. Screw the fixing screw into the Installation Module

from below to fix the Installation Module in place.

For even better vibrational noise rejection, you can fix
the Installation Module to the tabletop with an optional
H 600 + A 608 shock mount (see figs. 15 and 16).

1. Plug the cable of the DPA phantom power adapter

into the female mini XLR connector on the connecting
cable of the Installation Module.

2. Use a shielded cable to connect the DPA phantom

power adapter to a microphone input with phantom
power.

3. If the phantom power on your mixing console is

switchable, switch the phantom power on. (Refer to
the instruction manual for your mixing console.)
The Capsule Module and the LED ring will be pow-
ered from the phantom supply.

You may also connect the GN 15, GN 30, and GN 50 in-
stallation modules to a PT 40, PT 400, or PT 4000 body-
pack transmitter from AKG. All you need to do is change
the wiring of the mini XLR connector as shown in fig. 6
on page 35:

DISCREET ACOUSTICS modular

Voltage

Req`d resistor

Max. power

6 V

390

0.1 W

12 V

1k

0.25 W

24 V

2.2 k

0.25 W

48 V

4.7 k

0.5 W

4513_09_BDA_DAM_Hex0909_ps.qxd 11.09.2009 10:45 Uhr Seite 34