Recommended CAT5
Cable Lengths
CAT5 cable lengths and the number of
CAT5 wire pairs determine the number
of digital call switches that can be dai-
sy-chained. (See Figure 2.)
Length limits are due to voltage drop
across the power conductors. For 2-pair
or 3-pair, it is best to tie the solids togeth-
er and to tie the stripes together at each
end of a long run. This will make it easier
to keep up with which wires are V+ and V-.
CAUTION:
These calculations are based on standard 24 AWG solid copper wire. Calculations will not be
accurate for copper-plated aluminum wire or wire guage less than 24 AWG.