beautypg.com

Vrd-1ff – Jensen Transformers Iso-Max VRD-1FF - Single-Channel CATV Ground Isolator (F Connectors) User Manual

Page 2

background image

Jensen...The Worlds Finest Audio Transformers

Jensen Transformers Inc., 9304 Deering Ave. Chatsworth, CA 91311

P: (818) 374-5857 F: (818) 374-5856 [email protected]

jensen-transformers.com

CATV

Residential

“Drop”

SHIELD

GROUND*

ISO-MAX

VRD-1FF

VRD-1FF

PARAMETER

CONDITIONS

MINIMUM

TYPICAL

MAXIMUM

Insertion loss

5 MHz, HP 3577A Analyzer

-0.19 dB

50 MHz, HP 3577A Analyzer

-0.01 dB

-0.1dB

Bandwidth

LF -3 dB re 100 MHz, HP 3577A Analyzer

1 MHz

1.2 MHz

HF -3 dB re 100 MHz, HP 8711A Analyzer

1000 MHz

> 1300 MHz

VSWR, input or output port

50 MHz to 866 MHz, HP 8711A Analyzer

1.08

(see graph)

1.2

Input to output voltage

200 V DC

Externally Radiated Field at 3 Meters

Ref. level = 1.414mVrms, Frequency = 50MHz

1.1uV/meter

Ref. level = 1.414mVrms, Frequency = 500MHz

4.8uV/meter

Ref. level = 1.414mVrms, Frequency = 1GHz

6.3uV/meter

Margin below FCC part 76 Limits

Ref. level = 1.414mVrms, Frequency = 50MHz

25.6dB

Ref. level = 1.414mVrms, Frequency = 500MHz

12.5dB

Ref. level = 1.414mVrms, Frequency = 1GHz

10.1dB

Cable length

input
output

Isolation Impedance

output shield to input shield, 60 Hz

1 MΩ

1.3 MΩ

All minimum and maximum specifica

-

tions are guaranteed. Unless noted

otherwise, all specifications apply at

25

°

C. Specifications subject to change

without notice. All information herein

is believed to be accurate and reliable,

however no responsibility is assumed

for its use nor for any infringements of

patents which may result from its use.

No license is granted by implication or

otherwise under any patent or patent

rights of Jensen Transformers, Inc.

*IMPORTANT NOTE: THIS PRODUCT

IS NOT INTENDED FOR USE IN

CIRCUMSTANCES WHERE THE DC

OR PEAK AC VOLTAGE BETWEEN

INPUT AND OUTPUT CONNECTIONS

EXCEEDS 34 VOLTS OR WHERE ITS

FAILURE COULD CAUSE INJURY OR

DEATH.

Source Z = load Z = 75 Ω, signal level = -20 dBm

* For maximum protection from lightning strikes, a good low impedance

ground is necessary. Most local codes require this at building entry.

AMPLITUDE (dB) vs FREQUENCY (MHz)

REFLECTION COEFFICIENT (dB) and VSWR vs FREQUENCY (MHz)

VSWR

REFLECTION COEFFICIENT

1.0

0

0.0

-10

1.924

-20

1.222

-30

1.065

-40

1.020

-50

1.006

-60

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

0

0

100

100

200

200

300

300

400

400

500

500

600

600

700

700

800

800

900

900

1000

1000

1100

1100

1200

1200

1300

1300