Figure 1 - reverse return path – Blonder Tongue BIDA-5900 Series Broadband Indoor Distribution Amplifier with Power Doubling (30 dB, 54-1000 MHz) User Manual
Page 6
6 BIDA 5900 Series
User Manual
FLAT
ATTENUATOR
OPTION
BIDA-FA
5411A
CABLE
EQUALIZER
OPTION
BIDA-CE
547X
HYBRID
AMP 1
GAIN
CONTROL
FULL
SLOPE
CONTROL
FLAT
HYBRID
AMP 2
OUTPUT/INPUT
-30 dB
TEST
GAIN
CONTROL
CIRCUIT
SLOPE
CONTROL
CIRCUIT
54 MHz HPF2
42 MHz LPF2
ATT
INPUT/OUTPUT
-30 dB
TEST
54 MHz HPF1
42 MHz LPF1
ATT
GAIN
CONTROL
FULL
GAIN
CONTROL
J11
+24V
J13
P3
P1
FLAT
ATTENUATOR
PASSIVE
PASSIVE
ACTIVE
ACTIVE
P2
ON
OFF
J12
RETURN
AMPLIFIER
PASSIVE RETURN PATH
NOTE:
Passive Return Path: Short Plug P1 on J11
and P3 on J13 to “passive” and P2 on J12 to “off”.
Active Return Path: Short Plug P1 on J11 and P3 on
J13 to “active” and P2 on J12 to “on”.
Figure 1 - Reverse Return Path
THERE ARE NO USER SER VICE ABLE PARTS IN THIS UNIT.
THE FOLLOWING INFORMATION IN THIS MANUAL IS FOR QUALIFIED INSTALLATION PERSONNEL ONLY
Field Installable Optional Modules.
Take care not to bend jack pins when plugging in modules - view orientation of pins through holes provided - pins are polarized to prevent
wrong installation - see Location Diagram.
Leakage-current and/or resistance measurements should be made by service technician after repairs are completed to determine that exposed
parts are acceptably insulated from the supply circuit.