EverFocus Speed Dome EPTZ3000I User Manual
Page 15

2-14
2.3.1. Address Setting
The address code of the EPTZ3000/EPTZ3000I should be set to correspond properly
with a control device to control multiple dome cameras. The address codes are made
up by the dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the
binary coded of the address, and there are 256 addresses can be selected (0 ~ 255, 2
8
= 256). It also means that there are up to 256 dome cameras that can cascade on the
RS-485 bus. The dipswitch setting and the indicated address are represented in the
following chart.
Note: The factory default address is 1.
Notice: Please make sure the power is off before setting, and restart the
EPTZ3000/EPTZ3000I to enable a new value after changing.
SW1
O
N
1
2
3
4
5
6
7
8
CPU
O
N
1
2
3
4
5
6
7
8
SW2
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
P
ro
to
c
o
l
B
A
U
D