Datavideo WM-11 Wall Mount for PTR-10 MK II and PTR-10T MK II User Manual
Page 9
9
4.
Place the round rod in between the left and right brackets then
secure it in position by fastening two
M5x20 nickel plated hex
socket cap screws
to the respective holes on the brackets as
shown in the diagram below.
5.
Use four M2.5 screws to mount two bubble level meters to the
base plate with one in the front and one at the bottom.
Insert the base plate between the left and right brackets then
secure it in position by fastening six
M5x20 nickel plated hex
socket cap screws
to the respective holes on the brackets as
shown in the diagram below. By inspecting the bubble level meter,