Repairs, Environmental protection, Available accessories – Elektra Beckum Submersible Well Pump TP 7000 S User Manual
Page 6: Technical specifications, English

11
ENGLISH
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
For this equipment the following acces-
sories are available at specialist dealers.
Note:
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
A
Elbow
Inlet port thread:
1 1/4" male
Discharge port thread:
1" female + 1 1/4" male
9.
Repairs
10. Environmental Protection
11. Available Accessories
12. Technical Specifications
Mains voltage
V 230
∼
1
Frequency
Hz 50
Rated output
W 350
Rated current
A 1.5
Fuse protection min. (time-lag or L-type circuit breaker)
A
10
Running capacitor
µ
F 8
Rated speed
min
-1
2800
Pump capacity max.
l/h
7000
Delivery head max.
m 7
Delivery pressure max.
bar
0.7
Immersion depth max.
m
5
Standing water max.
mm
15
Temperature of the primed medium max.
°C 35
Degree of protection
IP 68
Degree of protection
I
Insulation class
B
Materials
Pump casing
Pump shaft
Impeller
Polypropylene
Stainless steel
Noryl
Power cable (HO 7 RN-F)
m
10
Discharge port
1 1/4 female
Dimensions (pump casing)
Height
Width
Diameter
mm
mm
mm
260
180
130
Weight
kg 4.5
Max. length of extension cable
at 3 x 1.0 mm
2
lead cross-section
at 3 x 1.5 mm
2
lead cross-section
m
m
60
100