beautypg.com

Emerson Process Management 99 User Manual

Type 99 pressure reducing regulators, Type 99, Introduction

background image

Type 99

D100260X012

Instruction Manual

Form 589

April 2008

www.emersonprocess.com/regulators

Type 99 Pressure Reducing Regulators

Introduction

Scope of the Manual

This manual describes and provides instructions and

parts lists for Type 99 pressure reducing regulators

complete with standard P590 Series integral filter.

However, complete instructions and parts listing for the

Type 1301F pilot supply regulator, and other Fisher

®

equipment, such as monitoring pilots will be found in

separate instruction manuals.

Description

The Type 99 gas regulators provide a broad capacity

for controlled pressure ranges and capacities

in a wide variety of distribution, industrial, and

commercial applications.
A Type 99 regulator has a Type 61L (low pressure),

Type 61H (high pressure), or a Type 61HP (extra

high pressure) pilot integrally mounted to the actuator

casing as shown in Figure 1. The Type 99 regulator

can handle up to 1000 psig (69,0 bar) inlet pressures

(the 1000 psig (69,0 bar) regulator requires a

Type 1301F pilot supply regulator and a Type H110 pop

relief valve). The pilot supply regulator reduces inlet

pressure to a usable 200 psig (13,8 bar) for the extra

high pressure pilot. This regulator comes standard with

O-ring seals on the guide bushing and valve carrier

(key 26, Figure 7) to keep main valve body outlet

pressure from interfering with outlet pressure in the

lower casing assembly (key 29, Figure 9).

Specifications

!

WaRnIng

Since a pilot-operated regulator is

constructed of both a pilot and a main

valve, care should be used not to exceed

the maximum inlet pressure shown on

the nameplate of either unit. When inlet

pressure exceeds the pilot limitation, a

pilot supply reducing regulator and/or

relief valve will be required.

Specifications and ratings for various Type 99

constructions are listed in the Specifications section

on page 2. Some specifications for a given regulator

as it originally comes from the factory are stamped

on nameplates located on the pilot and actuator

spring cases. A tag (key 159, Parts List) additionally

may be installed on the pilot to indicate a regulator

with O-ring stem seal. These regulators and their

installations should be checked for compliance with

applicable codes.

Figure 1. Type 99 Regulator with Type 61H (high pressure) Pilot

W2676