beautypg.com

Introduction specifications – Empire Comfort Systems BF-30-2 User Manual

Page 5

background image

16943-5-0806

Page 5

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip-

ment or accessories and repair and servicing of equipment shall

be performed only by a qualified agency. The term "qualified

agency" means any individual, firm, corporation, or company that

either in person or through a representative is engaged in and is

responsible for (a) the installation, testing, or replacement of gas

piping or (b) the connection, installation, testing, repair, or servic-

ing of equipment; that is experienced in such work; that is familiar

with all precautions required, and that has complied with all the

requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a

licensed plumber or gas fitter in the Commonwealth of Mas-

sachusetts.
Sellers of unvented propane or natural gas-fired supplemental

room heaters shall provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane and natural

gas-fired space heaters shall be prohibited in bedrooms and

bathrooms.

The installation must conform with local codes or, in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1/

NFPA54.*

*Available from the American National Standards Institute, Inc., 11 West 42nd

St., New York, N.Y. 10036.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be

reduced at the rate of 4 percent for each 1,000 (305m) feet above

sea level. Contact the manufacturer or your gas company before

changing spud/orifice size.
Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect

the Btu output of the unit. Contact the gas company for the heat-

ing value. Contact the manufacturer or your gas company before

changing spud/orifice size.

Instructions to Installer

1. Installer must leave instruction manual with owner after instal-

lation.

2. Installer must have owner fill out and mail warranty card sup-

plied with unvented room heater.

3. Installer should show owner how to start and operate unvented

room heater.

Always consult your local Building Department regarding regu-

lations, codes or ordinances which apply to the installation of an

unvented room heater.
This appliance may be installed in an aftermarket* permanently

located, manufactured (mobile) home, where not prohibited by

state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from

the manufacturer.

This appliance is only for use with the type of gas indicated on the

rating plate. This appliance is not convertible for use with other

gases.
General Information

This BF-10, BF-20 and BF-30 are design certified in accordance with

American National Standards Institute Z21.11.2 by the Canadian

Standards Association as an Unvented Room Heater and should

be installed according to these instructions.
Any alteration of the original design, installed other than as shown

in these instructions or use with a type of gas not shown on the

rating plate is the responsibility of the person and company mak-

ing the change.

WARNING: This appliance is equipped for (natural gas or

propane) gas. Field conversion is not permitted.

Important

All correspondence should refer to complete Model Number, Serial

Number and type of gas.

*SRS-18 floor stand can not be used in a bedroom installation.

BF-10 must be wall mounted in a bedroom installation.
The bedroom must be an unconfined space. ANSI Z223.1/NFPA 54 defines an unconfined space as "a space whose volume is not less

than 50 cubic feet per 1,000 Btu per hour (4.8m

3

per kw) of the aggregate input rating of all appliances installed in that space."

Specifications

Model

BF-10

BF-20

BF-30

Input Btu/HR (KW/H)(LP)

Input Btu/HR (KW/H)(NAT)

10,000 (2.9)

10,000 (2.9)

20,000 (5.8)

18,000 (5.3)

30,000 (8.8)

30,000 (8.8)

Height

22" (559mm)

22" (559mm)

22" (559mm)

Width

18" (457mm)

18" (457mm)

24 1/8" (536mm)

Depth

6 1/2" (165mm)

6 1/2" (165mm)

6 1/2" (165mm)

Gas Inlet

3/8" (10mm)

3/8" (10mm)

3/8" (10mm)

Accessories
Blower

SRB-18T

SRB-18T

SRB-30T

Floor Stand

SRS-18*

SRS-18

SRS-320

INTRODUCTION

SPECIFICATIONS

This manual is related to the following products: