GENERAL FEATURES

POWER SWITCH

Controls the power as 3 different level (3,4,7 kW) to adjust the water
temparature.

INDICATION LAMPS

The lamp at the top indicates the power, the other lamps indicate power
levels.

DIAPHRAGM GROUP

This sophisticated group controls the power depending on the differen-
tial pressure on both sides of rubber membrane. It shuts of the power
when the differential pressure is not enough.

THERMOSTAT

Prevents the over heating of the water by shutting off the heating
element.

RESET THERMOSTAT

It is a double safety feature for over heating. If thermostat is failed its
function, reset thermostat prevents over heating.

HOW TO OPERATE

1. Turn on the water tap. (Figure 1)
2. Adjust the flow rate by using the spherical valve. (Figure 2)
3. Depending on the season and water temparature desired, the selector
switch should be positioned to the desired level of 1,2 or 3.
4. To turn off your water heater, the power selector switch should be at
“0” position first. Wait until water cools down.
5. When water cools down, close the water tap.
6. This shut off prosess will protect the heater resistance against lime
scale deposits resulting decrease on heating and resistance failure.

Figure 1

Figure 2

Figure 3

MAINTENANCE

1. The maintenance of the appliance must be performed by an authorized
service personal only.
2. Before any maintenance or service, turn off the main power of the house.
Make sure that the power is off by checking with a voltmeter.
3. If the water has too much lime, a water purificating system is recommend-
ed to purify water. The failures caused by lime scale deposits is not under
warranty.
4. For open outlet water heaters used with spray head and spray head must
be descaled regularly.
5. Clean the front casing with a cloth using detergent. (do not use gasoline,
solvent, thinner, etc. for cleaning the case)

INSTALLATION MOUNTING OF DEVICE FOR

OPEN OUTLET (MODEL 105MC...)

Mounting of Device to Shower and Parts to be used

MOUNTING OF DEVICE

FOR CLOSED OUTLET

(MODEL 105MC..C)

Mounting of Device to Main Pipe Line

* Water inlet and outlet of the device
is R 1/2”.
* Connect the blue colour cold
water inlet pipe to cold water pipe
line with a flexible hose.
* Connect the red colour hot water
outlet pipe to hot water pipe line with
a flexible hose.

CAUTION !

The water outlet
must not be connected to
any tap/valve or fitting other
than those specified.

WARNING:

All poles shall be disconnection with contact opening at least 3.5

mm means for disconnection must be incorporated in the fixed wiring should be in
accordance with the national wiring rules. The appliance must be connected to water
supply should be according the national installation rules.

MOUNTING DIAGRAM

Figure 1

Figure 2

Figure 3

Figure 4

The cable connections of the product are

made, the package is opened at the front

side for wall mounting, the card cable is

removed from the card

The ends of the antigron cable are

exposed, a hole is made in the sealing

gasket and it is mounted on the back cover

The back cover is fixed on the wall at 4

points using dowels and screws

The cable is fixed with a cable clamp and

the end of the cable is screwed into the

connector

Figure 5

Figure 6

After the back cover is fixed onto the wall, the card cable on

the back cover is mounted upon the card on the front

cover, then the front cover is fixed

After the back cover is

fixed onto the wall, screw

the front box