beautypg.com

Bottom drain plug, Continuous drain hose – MIDEA MAP08R1CWT User Manual

Page 9

background image

NOTE

Make sure the hose is secure so there are
no leaks. Direct the hose toward the drain,

m

aking sure that there are no kinks that

will stop the water flowing. Place the end
of the hose into the drain and

m

ake sure

the end of the hose is down to let the
water flow s

m

oothly. When the

continuous drain hose is not used, ensure
that the drain plug and knob are installed
fir

m

ly to prevent leakage.

Water drainage

• During dehumidifying modes, remove the drain

plug from the back of the unit and install the drain
connector (5/8” universal female mender) with 3/4”
hose (locally purchased). For models without drain
connector, just attach the drain hose to the hole. Place
the open end of the hose directly over the drain area in
your basement floor.

Remove the
drain plug

Continuous
drain hose

• When the water level of the bottom tray reaches

a predetermined level, the unit beeps 8 times.
The digital display shows “P1.” At this time the
air conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate (this is normal). Carefully move
the unit to a drain location, remove the bottom
drain plug and let the water drain away. Reinstall
the bottom drain plug and restart the machine until
the “P1” symbol disappears. If the error repeats, call
for service.

Bottom drain plug

NOTE

Be sure to reinstall the botto

m

drain plug fir

m

ly to

prevent leakage before using the unit.

Oper

ating

Ins

tructions

Page 9