ASCII Protocol Configuration
ASCII ♦ ProLinx Standalone
Generic ASCII Serial Communication Module
ProSoft Technology, Inc.
Page 19 of 40
July 7, 2008
4
ASCII Protocol Configuration
In This Chapter
Port 0] ........................................................................................ 19
In order for the ASCII driver to function, a minimum amount of configuration data
must be transferred to the module from the module's file system. Care must be
taken in constructing the module configuration parameters. If the module does
not function as expected, examine the configuration file using the Debugger Port
on the module. All configuration parameters for the driver are found under the
[ASCII Port x] section. The x in the section name will have a value of 0 to 3
corresponding to the appropriate ASCII port.
After setting up the configuration file, download it to the module using ProSoft
Configuration Builder.
4.1
[ASCII Port 0]
[ASCII PORT 0]
Enabled : Y #
RS Interface : 0 #0=RS-232, 1=RS-485, 2=RS-422
Rx DB Start : 200
Tx DB Start : 0
Baud Rate : 19200
Parity : N #The coded values are as follows: N=None, O=Odd,
# E=Even, M=Mark and S=Space."
Data Bits : 8 #Valid entries for this field are 5, 6, 7 and 8."
Stop Bits : 1
RTS On : 0
RTS Off : 0
Handshaking : N #Handshake code of N, Y, D, X"
Rx Termination Type: 1
Rx Term Count : 1
Rx Term Chars : 13 11 12 14 15 16 17 255 255 0 0 0
Rx Packet Length : 10
Rx Timeout : 5000
Rx Delay : 1000
Swap Rx Data Bytes : N
Tx Timeout : 5000
Tx Minimum Delay : 0
Swap Tx Data Bytes : N
4.1.1 Enabled
Yes or No
This flag specifies if the port on the module will be utilized. If the parameter is set
to No, the port will not be used. If the parameter is set to Yes, the port will be
used supporting the ASCII protocol.