Amprobe LAN-1 Lan-Cable-Tester User Manual
Page 8

7
tESt ExAmPLES
Continuity
green o n o o o o o o o
pin 2 has continuity
1 2 3 4 5 6 7 8 g
Red
o n o o o o o o o
open
green o n o o o o o o o
pin 2 is open
1 2 3 4 5 6 7 8 g
Red
o o o o o o o o o
Short
green o n n o o o o o o
pins 2 and 3 are shorted
1 2 3 4 5 6 7 8 g
Red
o n n o o o o o o
miswire
green o n o o o o o o o
pins 2 and 6 are miswired
1 2 3 4 5 6 7 8 g
Red
o o o o o n o o o
SPECIfICAtIoNS
general
display:
Red and green Led’s
Battery:
9V, 006p or ieC 6f22 or NedA 1604.
Low Battery indicator:
The Led indicator will not turn oN when
BATT button pushed
Battery Life:
Approx 20 hours. (Alkaline battery)
environment:
indoor operation, maximum altitude
- 2000 m (6561 ft.)
Temperature / humidity:
operation:
0 to 40°C (32 to 104°f), 10 to 70% Rh.
Storage:
-10 to 60°C (14 to 140°f), 10 to 90% Rh.
dimension:
130 x 64 x 38mm (5.1 x 2.2 x 1.5 in)
weight:
1.26 kg (0.6 lb)
�
-eMC: eN61326-1 This product complies with requirements of the
following european Community directives: 89/336/eeC (electromagnetic
Compatibility) and 73/23/eeC (Low Voltage) as amended by 93/68/eeC (Ce
Marking). however, electrical noise or intense electromagnetic fields in the
vicinity of the equipment may disturb the measurement circuit. Measuring