beautypg.com

Amprobe UDM45 Ultrasonic-Distance-Meter User Manual

Page 8

background image

7

Calculation of area / volume

press ‘ReAD’ to measure the length.

1.

press ‘x/=’ to enter the multiplication mode.

2.

press ‘ReAD’ to measure the width.

3.

press ‘x/=’ and the calculated value of area is displayed in ‘sq.’

4.

press’ ReAD’ to measure the height.

5.

press ‘x/= ’and the result of he calculated volume is displayed in ‘cu.’

6.

To end the area/volume calculation, just press ‘ReAD’ twice.


note:
1. ‘+’and the times of adding will appear on the display during addition operation (but when
you press it more than 9 times, ‘-‘displays); even more, adding can be done continuously.
2. The sum of the measurements cannot be used as an operand for multiplication.

MAINtENANCE AND REPAIR
if there appears to be a malfunction during the operation of the meter, the following steps
should be performed in order to isolate the cause of the problem:

Check the battery.

1.

Review the operating instructions for possible mistakes in operating procedure.

2.

inspect and test the test leads for a broken or intermittent connection.

3.
except for the replacement of the battery or test probes, repair of the multimeter should be
performed only by a factory Authorized Service Center or by other qualified instrument service
personnel. The front panel and case can be cleaned with a mild solution of detergent and
water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use
aromatic hydrocarbons or chlorinated solvents for cleaning.

battery Replacement

Warning

Battery replacement should be performed in a clean environment and with appropriate care
taken to avoid contaminating the meter’s interior components.

Compress the tab and lift battery cover.

1.

Replace the battery with the same type, 9-volt battery.

2.

note polarity of the battery.
Replace the battery cover.

3.

SPECIfICAtIoNS
general
Display:

4 digit lCD

power supply:

9V Alkaline type 6f22 Battery