beautypg.com

Amprobe ACD-6-PRO Clamp-On-Multimeters User Manual

Page 14

background image

13

ACA Current (Clamp-on)
RANGE

Accuracy

1) 2) 3)

50Hz / 60Hz
400.0A

1.5% + 5d

1000A

1.5% + 5d*

True RMS model ACD-6 TRMS PRO Crest

Factor:

< 2.6 : 1 at full scale & < 5.2 : 1 at half

scale

1)

Add 8d to specified accuracy while reading

is below 15% of range

2)

Induced error from adjacent current-

carrying conductor: < 0.06A/A

3)

Specified accuracy is for measurements

made at the jaw center. When the
conductor is not positioned at the jaw
center, position errors introduced are:
Add 1% to specified accuracy for

measurements made WITHIN jaw
marking lines (away from jaw opening)

Add 4% to specified accuracy for

measurements made BEYOND jaw
marking lines (toward jaws opening)


This manual is related to the following products: