Electrical specifications, Voltage, Resistance and continuity & diode – Amprobe AC71B Clamp-On-Multimeter User Manual
Page 11

88
9
Electrical Specifications
Accuracy
± (% reading + number of digits) at 3 °C ± 5 °C at < 80 % R.H.
Temperature Coefficient
Add 0. x (Specified Accuracy) / °C, < 8 °C, > 8 °C
Voltage
Function
Range
Accuracy
V �
.3 V to 750.0 V
±(.5% + 3 dgts)
50 Hz – 500 Hz
V �
. V to 000 V
±(% + dgts)
-0.7 V to 000 V
±(% + 4 dgts)
Overload Protection: 000 VDC / 750 VAC
Max Operation Time: DT = 30s for ≥ 30 V
Input Impedance: ≥ 4 kΩ for input voltage up to 30 V.
Impedance increases with input voltage to approximately 375
kΩ at 750 VAC.
Resistance and Continuity & Diode
Function
Range
Accuracy
Ω �
0 Ω to 9999 Ω
±(% + dgts)
�
0.4 V to 0.8 V
±(% + 3 dgts)
Maximum Open Circuit Voltage: .0 V
Overload Protection: 000 VDC / 750 VAC
Continuity Check
Internal sound activates if the resistance of the circuit under
test is less than 5 Ω. It will then turn off if the resistance is
increased beyond 400 Ω. Specified from 0
°C
to 40
°C.
- AC50A (78 pages)
- ACD-10-TRMS-Pro (16 pages)
- AC68C Clamp-Multimeter (52 pages)
- ACD-14-TRMS-FX Clamp-On-Multimeter (19 pages)
- ACD-10-TRMS-PLUS ACD-10-PLUS Clamp-Multimeters (116 pages)
- ACD-40PQ Clamp-Meters (16 pages)
- ACD-23SW Digital-Clamp-Meters (20 pages)
- ACD-41PQ Clamp-On-Power-Meters (20 pages)
- ACD-41PQ Clamp-On-Power-Meters (121 pages)
- ACD-14-TRMS-PLUS Clamp-On-Multimeters (148 pages)
- ACD-330T Clamp-On-Multimeter (42 pages)
- ACD-21SWC Digital-Clamp-Meters (84 pages)
- ACD-4 Mini-Clamp-DMM (16 pages)
- ACD-6-TRMS-PRO Clamp-On-Multimeters (15 pages)
- FLASH-80 Industrial-Mini-Flashlight (64 pages)
- FLASH-80 Industrial-Mini-Flashlight (46 pages)
- FLASH-80 Industrial-Mini-Flashlight (44 pages)
- FLASH-80 Industrial-Mini-Flashlight (98 pages)
- ACD-50NAV ACD-51NAV ACDC-52NAV ACD-53NAV ACD-54NAV Navigator-Clamps (36 pages)
- ACD-55HPQ Clamp-Meter (62 pages)
- ACDC-620T Clamp-On-Multimeter (65 pages)
- ACDC-400 Digital-Clamp-On-Multimeter (98 pages)
- ACDC-100-TRMS Clamp-On-Multimeters (97 pages)
- RS-3 Rotary-Scale-Clamp-On (4 pages)
- AD105A Clamp-Meter (34 pages)
- LH41A Clamp-On-Ammeter (53 pages)
- 30XR-A Professional-Digital-Multimeter (53 pages)
- 33XR-A Professional-Digital-Multimeter (73 pages)
- 34XR-A Professional-Digital-Multimeter (73 pages)
- 37XR-A Professional-Digital-Multimeter (86 pages)
- 5XP-A 15XP-A 35XP-A Compact-Digital-Multimeters (126 pages)
- AM-110-TRMS Digital-Multimeters (15 pages)
- AM-160-A DMM (30 pages)
- 38XR-A Professional-Digital-Multimeter (92 pages)
- AM-33 Digital-Multimeter (1 page)
- AM-34 Auto-Digital-Multimeter (1 page)
- AM-47 Multimeters (8 pages)
- AM-240 Digital-Multimeters (75 pages)
- AM-250 Digital-Multimeter (22 pages)
- AM-270 Industrial-Multimeter (28 pages)
- AM-60 Compact-Digital-Multimeter (20 pages)
- AM8C Analog-Multimeter (66 pages)
- CR50A Capacitance-Resistance-Meter (46 pages)
- AM91RS Digital-Multimeter (30 pages)