Electrical data – Amprobe CT238A ACDC-Current-Probe User Manual
Page 8
2
Specifications
Electrical data
(All accuracies stated at 23°C ± 1°C)
Nominal current In
20 A r.m.s
Measuring range
0 to ±30 A
Overload capacity
500A
Overall DC accuracy
±1% of reading ±2mA
AC accuracy, <1kHz
±1% of reading 2mA
1kHz to 20kHz: ±3% of reading ±2mA
Resolution ±1mA
Typical output noise level
200µV r.m.s.
Gain variation
±0.01% of reading/°C
Output sensitivity
100mV/A
Frequency range
DC to 20 kHz
di / dt following
20A/µs
Response time
better than 1 µs
Dielectric strength
3.7kV rms 50Hz 1 min
Safety: Meets EN61010-1 Cat III 300V; EN61010-2-032
EMC: Meets EN50081-1, EN50082-1
�
EMC: This product complies with requirements of
the following European Community Directives: 9/336/EEC (Electromagnetic
Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE
Marking).
General data
Operating temperature
0°C to +50°C
Storage temp., battery removed 20°C to +85°C
Environment
-
indoor use
-
altitude up to 2000m
-
maximum relative humidity 80% for temperatures up to 31°C decreasing
linearly to 40% relative humidity at 50°C.
Power supply
9 V Alkaline battery PP3, NEDA 1604 or
IEC6F22
Battery life
30 hours typical
Load impedance (minimum)
> 10k � and ≤100pF
Conductor size
19 mm diameter
Jaw opening
20 mm max.
Weight
250 g.
Output cable and connectors
1.5m long terminated with
4mm safety plugs.