beautypg.com

Electrical data – Amprobe CT238A ACDC-Current-Probe User Manual

Page 8

background image

2

Specifications

Electrical data

(All accuracies stated at 23°C ± 1°C)
Nominal current In

20 A r.m.s

Measuring range

0 to ±30 A

Overload capacity

500A

Overall DC accuracy

±1% of reading ±2mA

AC accuracy, <1kHz

±1% of reading 2mA

1kHz to 20kHz: ±3% of reading ±2mA

Resolution ±1mA

Typical output noise level

200µV r.m.s.

Gain variation

±0.01% of reading/°C

Output sensitivity

100mV/A

Frequency range

DC to 20 kHz

di / dt following

20A/µs

Response time

better than 1 µs

Dielectric strength

3.7kV rms 50Hz 1 min

Safety: Meets EN61010-1 Cat III 300V; EN61010-2-032
EMC: Meets EN50081-1, EN50082-1

EMC: This product complies with requirements of

the following European Community Directives: 9/336/EEC (Electromagnetic
Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE
Marking).
General data
Operating temperature

0°C to +50°C

Storage temp., battery removed 20°C to +85°C
Environment
-

indoor use

-

altitude up to 2000m

-

maximum relative humidity 80% for temperatures up to 31°C decreasing
linearly to 40% relative humidity at 50°C.

Power supply

9 V Alkaline battery PP3, NEDA 1604 or
IEC6F22

Battery life

30 hours typical

Load impedance (minimum)

> 10k and ≤100pF

Conductor size

19 mm diameter

Jaw opening

20 mm max.

Weight

250 g.

Output cable and connectors

1.5m long terminated with
4mm safety plugs.