beautypg.com

Technical details – Electrolux EKG5047 User Manual

Page 27

background image

27

TECHNICAL DETAILS

DIMENSIONS

Height:

900

mm

(nominal)

Width:

500

mm

(nominal)

Depth:

600 mm (to front of door panel)

Weight:

54

.4

Kg Net

Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level. See important note 'Location of Appliance'.
Minimum space above hotplate 750mm (If cooker hood is fitted refer to the cooker hood installation instructions.

Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel)

CONNECTIONS


Gas connection: -

Rear left hand side of appliance at hotplate level
Rc ½ (½” B.S.P. female)

Electrical connection: -

None


IGNITION

Battery

1.5 Volt AA size

HOTPLATE

Natural Gas

Heat

Input

R.H.F

R.H.F

L.H.R

L.H.F

1.0kW

1.9kW 1.9kW

2.9kW

(3412 Btu/h)

(6483 Btu/h)

(6483 Btu/h)

(9895 Btu/h)

Injector

Marking

070

096

096

119

L.P.Gas

Heat

Input

1.0kW

1.9kW

1.9kW

2.8kW

(71.8g/h)

(136.5g/h)

(136.5g/h)

(194.0g/h)

Injector

Marking

050

071

071

086

GRILL

Natural Gas

L.P.Gas

Heat

Input

2.7kW

(9215 Btu/h)

2.7kW (176g/h)

Injector

Marking

121

78

SECOND OVEN

Heat

Input

2.4kW

(8189

Btu/h)

2.4kW (172.4g/h)

Injector Marking

108

078

Dual

Control

By-Pass

Fixed

Internal

Fixed

Internal

MAIN OVEN

Heat

Input

2.4kW

(8189Btu/h)

2.4kW ( 172.4g/h)

Injector Marking

108

78

Thermostat

By-Pass

Marking

69

48


GENERAL

Ignition

(H.T.

Spark)

Spark

Gap

3-4mm

GAS CATEGORY COUNTRIES OF DESTINATION

CAT. I

2H

GB

CAT. I

3+

GB

This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC ,Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68/EEC.

This manual is related to the following products: