Permanent connection, Building-in, Preparation and assembly of the door – DE DIETRICH WBD1211 User Manual
Page 21: Installation electrical connection, Installation
Permanent connection
In the case of permanent connection
it is necessary that you install a
double pole switch between the
appliance and the electricity supply
(mains), with a minimum gap of 3mm
between the switch contacts and of a
type suitable for the required load in
compliance with the current electrical
regulations.
The switch must not break the yellow
and green earth cable at any point.
IMPORTANT!
The power supply cable must be
easily accessible after installing the
appliance.
Building-in
This appliance has been designed to
be built into the kitchen furniture.
The recess should have the
dimensions shown in picture A.
P0965
820 min
600 min.
600
596
416
176,5
818
541
195
490
160
120
90
8
515
165
A
Preparation and assembly of
the door
The machine is originally pre-
arranged for the assembly of a door
opening from right to left.
In this case it is sufficient to screw in
the hinges (1) and the counter-
magnet (6) provided with the
appliance, at the right level (Fig. B).
a) Door
The dimensions of the door should
be:
- width
595-598 mm
- thickness 16-22 mm
The height (C-Fig. C) depends on the
height of the adjacent furniture's base.
b) Hinges
To mount the hinges it is necessary to
drill two holes (dia. 35 mm, depth 12.5-
14 mm depending on the depth of door
furniture) on the inner side of the door.
The distance between the holes hobs
fixing centres must be 416 mm.
The distance (B) from upper edge of
the door to the centre of the hole
depends on the adjacent furniture's
dimensions.
4
1
2
3
6
1
2
3
P0982
7
B
5
41
Installation
Electrical connection
Any electrical work required to install
this appliance should be carried out
by a qualified electrician or competent
person.
WARNING: THIS APPLIANCE
MUST BE EARTHED.
The manufacturer declines
any liability should this safety
measure not be observed.
Before switching on, make sure the
electricity supply voltage is the same
as that indicated on the appliance’s
rating plate. The rating plate is located
at the top of the rim of the open door.
The appliance is supplied with a
13amp plug fitted.
In the event of having to change the
fuse in the plug supplied, a 13amp
ASTA approved (BS1363 A) fuse must
be used.
Should the plug need to be replaced
for any reason, proceed as described
below.
Mod. ..........
Prod. No. ...........
Ser. No. .........
Mod.
..........
Ser.
P0042
The wires in the mains lead are
coloured in accordance with the
following code:
Green and Yellow
- Earth
Blue
- Neutral
Brown
- Live
The wire coloured green and yellow
must be connected to the terminal
marked with the letter «E» or by the
earth symbol
or coloured green
and yellow.
The wire coloured blue must be
connected to the terminal marked
«N» or coloured black.
The wire coloured brown must be
connected to the terminal marked «L»
or coloured red.
Upon completion there must be no
cut, or stray strands of wire present
and the cord clamp must be secure
over the outer sheath.
WARNING:
A cut off plug inserted into a
13 amp socket is a serious
safety (shock) hazard.
Ensure that the cut off plug is
disposed of safely.
GREEN & YELLOW
BROWN
CORD CLAMP
BLUE
13
A
P1041
E
N
L
40
Installation