Permanent connection

In the case of permanent connection
it is necessary that you install a
double pole switch between the
appliance and the electricity supply
(mains), with a minimum gap of 3mm
between the switch contacts and of a
type suitable for the required load in
compliance with the current electrical
regulations.

The switch must not break the yellow
and green earth cable at any point.

IMPORTANT!
The power supply cable must be
easily accessible after installing the
appliance.

Building-in

This appliance has been designed to
be built into the kitchen furniture.
The recess should have the
dimensions shown in picture A.

P0965

820 min

600 min.

600

596

416

176,5

818

541

195

490

160

120

90

8

515

165

A

Preparation and assembly of
the door

The machine is originally pre-
arranged for the assembly of a door
opening from right to left.
In this case it is sufficient to screw in
the hinges (1) and the counter-
magnet (6) provided with the
appliance, at the right level (Fig. B).

a) Door
The dimensions of the door should
be:
- width

595-598 mm

- thickness 16-22 mm

The height (C-Fig. C) depends on the
height of the adjacent furniture's base.

b) Hinges
To mount the hinges it is necessary to
drill two holes (dia. 35 mm, depth 12.5-
14 mm depending on the depth of door
furniture) on the inner side of the door.
The distance between the holes hobs
fixing centres must be 416 mm.
The distance (B) from upper edge of
the door to the centre of the hole
depends on the adjacent furniture's
dimensions.

4

1

2

3

6

1

2

3

P0982

7

B

5

41

Installation

Electrical connection

Any electrical work required to install
this appliance should be carried out
by a qualified electrician or competent
person.

WARNING: THIS APPLIANCE
MUST BE EARTHED.

The manufacturer declines

any liability should this safety
measure not be observed.

Before switching on, make sure the
electricity supply voltage is the same
as that indicated on the appliance’s
rating plate. The rating plate is located
at the top of the rim of the open door.

The appliance is supplied with a
13amp plug fitted.
In the event of having to change the
fuse in the plug supplied, a 13amp
ASTA approved (BS1363 A) fuse must
be used.
Should the plug need to be replaced
for any reason, proceed as described
below.

Mod. ..........
Prod. No. ...........

Ser. No. .........

Mod.
..........

Ser.

P0042

The wires in the mains lead are
coloured in accordance with the
following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

The wire coloured green and yellow
must be connected to the terminal
marked with the letter «E» or by the
earth symbol

or coloured green

and yellow.

The wire coloured blue must be
connected to the terminal marked
«N» or coloured black.

The wire coloured brown must be
connected to the terminal marked «L»
or coloured red.
Upon completion there must be no
cut, or stray strands of wire present
and the cord clamp must be secure
over the outer sheath.

WARNING:

A cut off plug inserted into a
13 amp socket is a serious
safety (shock) hazard.
Ensure that the cut off plug is
disposed of safely.

GREEN & YELLOW

BROWN

CORD CLAMP

BLUE

13

A

P1041

E

N

L

40

Installation