background image

7

3/4”

3/4” 1/2”

CH
DK

S

N

SF

3/4”

min 10

EN

Water Connection

Connection

Water inlet hose connection

There are two different types of water inlet hoses:

-Cold water inlet hose (up to 25°C)

- Hot water inlet hose (up to 60°C)

please check which one is applicable to your model.

If you are willing to connect your machine to natural

energy resources or to the central hot water supply, first

check out whether your water inlet hose type is suitable

by checking the temperature values written on the hose.

If your hose is not suitable, apply to your authorized

service to change the hose.

The water inlet hose is directly connected to the tap.

The water pressure coming from the tap must be

minimum 0.3 and maximum 10 bars.

Please use a valve if the water pressure exceeds 10

bars. Please turn on the tap and check for leakages

after connecting the hose. For safety reasons (if your

machine does not have the watersafe feature.) Please

ensure the tap is turned off when the machine is not

used;

For models with AQUABLOCK ,

If the water connection is made properly, this system

shall protect your house against floods.

The plastic frame of AQUABLOCK water intake system

has electrical components. Never allow contact with

water. Never cut the hose.

Appliance should be connected to the water mains with

the new hose set. The hose set of the previous machine

(if there is any) should be removed

3/4”