12
Instructions for the Installer
Engineers technical data
BURNER
ULTRA-RAPID
SEMI-RAPID
AUXILIARY
(triple crown)
(medium)
(small)
POSITION
M A X
MIN
M A X
MIN
M A X
MIN
NOMINAL THERMAL
POWER (kW)
3.8
1.20
1.9
0.45
1.0
0.33
NOMINAL FLOW
RATE (m
3
/h)
0.362
0.114
0.181
0.043
0.095
0.028
NOZZLE REFERENCE
146
Adjust.
96
Adjust.
70
Adjust.
(1/100 mm)
NOMINAL THERMAL
POWER (kW)
3.8
1.20
1.9
0.45
1.0
0.33
NOMINAL FLOW
RATE (g/h)
274
86
137
32.4
72
23.8
NOZZLE REFERENCE
98
40
71
32
50
28
(1/100 mm)
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Ultra-rapid
56
Aeration adjustment none
Supply Connections
Gas: RC 1/2 inch (1/2 inch male) Rear right
hand corner
Electric: 230 V 50 Hz supply, 3 core flexible
cable with non rewireable plug fitted with a 3
amp cartridge fuse.
Heat Input
Ultra-rapid Burner 3.8 kW Natural Gas
(Triple crown)
(12,966 BTU/HR)
3.8 kW L.P.G.
(12,966 BTU/HR)
Overall dimensions
Width:
880 mm
Depth:
510 mm
Cut out dimensions
Width:
830 mm
Depth:
480 mm
Semi-rapid Burner 1.9 kW (6,483 BTU/HR)
Auxiliary Burner
1.0 kW (3,412 BTU/HR)
Appliance class
3
Appliance category
II2H3+
Gas supply
Natural gas G 20 / 20 mbar
Instructions for the Installer