Eurotech Appliances Eurotech Ethernet Adapter An0038 User Manual
Page 10

10
Application
Note
Important Note. Connection to a 100BASE-TX hub for 100 Mbps operation requires Cat. 5 
Unshielded Twisted-Pair (UTP) cable or Cat. 5 Shielded Twisted-Pair (STP) cable. The maximum 
length between the 100BASE-TX hub and the adapter is 100 meters. Connection to a 10BASE-T hub 
for 10 Mbps operation requires a Cat. 3, 4, 5 UTP cable or Cat. 5 STP cable. Preferred maximum 
cable length between CPU-1220 module and Ethernet adapter is 10 cm (4”) 
Ethernet physical adapter Versions
This physical adapter is available in two different versions:
Table 4.
Physical Adapter code
EurotechCODE
Description
Valid for
RTL8139
ACS-9071-00
RJ45 ETHERNET ADAPTER FOR CPU-1220 AND CPU-1231
B
ACS-9071-03
RJ45 Ethernet adapter for CPU-1232 and CPU-1220
C
 
Warning: To prevent incorrect data transmissions select the proper physical adapter device 
depending on the Realtek RTL8139 chipset installed on the CPU-1220. 
 
Integration of the Ethernet physical adapter
If the Ethernet physical adapter has to be integrated over a custom circuitry, please refer to Eurotech for 
detailed information about schematics. 
 
Regarding schematics, a good choice is isolating the Ethernet adapter section from the rest of the power 
supply section. Derive the supply directly from the J4 Ethernet Connector of the CPU-1220. In this way if 
different versions of Realtek RTL8139 chipsets are installed no damage occurs when you connect J4 to the 
carrier board. 
 
 
 
 
Warning: please take care on the Realtek RTL8139 version used in order to avoid short-circuits 
between +5V and +3.3V when deriving power supply. 
 
 
