All installations and services must be performed by qualified service personnel.
4
B. CFM TABLES
The following tables contain blower speed settings and their respective air flowrates for the ECM blower motor. To
change air flowrates from that of the shipped settings, use the respective S3 and S4 dipswitches on the furnace’s
integrated control board (see Figure 1).
Dip
switch
settings Low fire CFM Rise (
o
F)
High Fire
CFM
Rise (
o
F)
Dip
switch
settings Low fire CFM
Rise (
o
F)
High Fire
CFM
Rise (
o
F)
7-OFF
8-OFF
760
64
931
70
7-OFF
8-OFF
760
60
931
70
7-ON
8-OFF
708
69
867
75
7-ON
8-OFF
708
65
867
75
7-OFF
8-ON
826
59
1012
65
7-OFF
8-ON
826
55
1012
65
7-ON
8-ON
909
54
1114
59
7-ON
8-ON
909
50
1114
59
Dip
switch
settings Low fire CFM Rise (
o
F)
High Fire
CFM
Rise (
o
F)
Dip
switch
settings Low fire CFM
Rise (
o
F)
High Fire
CFM
Rise (
o
F)
7-OFF
8-OFF
1015
64
1243
70
7-OFF
8-OFF
1015
60
1243
70
7-ON
8-OFF
947
69
1160
75
7-ON
8-OFF
947
64
1160
75
7-OFF
8-ON
1094
60
1340
65
7-OFF
8-ON
1094
56
1340
65
7-ON
8-ON
1184
55
1450
60
7-ON
8-ON
1184
51
1450
60
Dip
switch
settings Low fire CFM Rise (
o
F)
High Fire
CFM
Rise (
o
F)
Dip
switch
settings Low fire CFM
Rise (
o
F)
High Fire
CFM
Rise (
o
F)
7-OFF
8-OFF
1270
64
1556
70
7-OFF
8-OFF
1270
60
1556
70
7-ON
8-OFF
1185
69
1452
75
7-ON
8-OFF
1185
64
1452
75
7-OFF
8-ON
1366
60
1673
65
7-OFF
8-ON
1366
56
1673
65
7-ON
8-ON
1480
55
1813
60
7-ON
8-ON
1480
51
1813
60
=FACTORY SHIPPED SETTINGS
CDX1-125
CHX1-125
HEATING SPEEDS
CDX1-75
CHX1-75
CDX1-100
CHX1-100