Installation, Warning, Caution – England's Stove Works EVOLUTION PELLET STOVE 25-EP User Manual
Page 7: Unit clearances to combustibles
![background image](/manuals/84234/7/background.png)
Page | 7
INSTALLATION
Clearances to Combustibles
Unit Clearances to Combustibles
Side ( A )
Rear ( B )
Corner ( D )
Min. Alcove Height
Min. Alcove Width
6 IN.
6 IN.
4.5 IN.
51 IN.
38 IN.
152.4 MM.
152.4 MM.
114.3 MM.
1295.4 MM.
965.2 MM.
WARNING
• INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
• HOT! Do not touch! Severe burns or clothing ignition may result.
• Glass and other surfaces are hot during operation.
CAUTION
• Keep children away.
• Supervise children in the same room as this appliance.
• Alert children and adults to the hazards of high temperatures.
• Do NOT operate with protective barriers open or removed.
• Keep clothing, furniture, draperies and other combustibles away.
• Installation MUST comply with local, regional, state and national codes and
regulations.
• Consult local building, fire officials or authorities having jurisdiction about
restrictions, installation inspection, and permits.