The UltraMatrix AV can be instructed to switch any video input port to any video output port by sending a serial
command to the RS232 port. The serial HEX packet format that is sent to the UltraMatrix AV has the following structure:
Always 0xBE
Always 0xEF
Frame address set by the manufacture
Always 0x00 - Reserved for future use
Command byte
Number of bytes for the associated CMD
XOR of all bytes in the string except the BCC byte
Set the communication program up with the below settings. The program must be capable of sending HEX commands
to the unit.
Baud Rate
9600
Start Bits
1
Data Bits
8
Parity
None
Stop Bits
1
Example:
The command to switch input #1 to output #1 for the main unit with a frame address of 00 is:
BE EF 00 00 00 00 00 51
To calculate the BCC HEX value, convert each byte to its binary equivalent as shown below
BE 10111110
EF 11101111
00
00000000
00
00000000
00
00000000
00
00000000
00
00000000
--------------
XOR result
01010001
Hex equivalent 5 1
To arrive at the XOR result, look at each column and note the number of 1s. If there is an even number of 1s or all
zeroes in a column, the result for that column is zero. The result is 1 if there is an odd number of 1s in the column.
To set input #2 to output #1 for the main unit with a frame address of 00 is:
0xBE 0xEF 0x00 0x00 0x00 0x01 0x00 0x50
BE 10111110
EF 11101111
00
00000000
00
00000000
00
00000000
01
00000001
00
00000000
--------------
XOR result
01010000