Fig. 2 Wiring Single Contact
Fig. 3 Wiring Double Contact (on the same zone)
Wiring Passive Infra-Red Detectors
It is essential when using Passive Infra-Red Detectors that you refer to the manufacturers
instruction as to the positioning and settings of the detector. This section is intended as a
guide to the wiring of the detectors.
Fig. 4 Wiring Single PIR
P
P
P
P
a
a
a
a
g
g
g
g
e
e
e
e
5
5
5
5
Note: Both detectors must be run on a single cable
from the Control Panel to the first detector
then the second. The 2K2 resistor must be in the
last/final detector.
Zone 12V 0V
D1
D2
3K3
2K2
5K6
Alarm N/C Tamper N/C
1st Detector
2nd Detector
+ Power -
Alarm N/C Tamper N/C
+ Power -
RKP
0V
D1
Zone 12V
D2
5K6
2K2
3K3
2nd Detector
Door Contact
Alarm N/C Tamper N/C
+ Power -
RKP
Alarm
Notes
Positions of terminals will vary
according to make.
All PIR wiring diagrams apply
also to Dual Technology
Detectors and Vibration sensors.
Fig. 5 Keypad Zones (480 RKP Only)
Note: Keypad zones (480
RKP Only) are preset
and cannot be changed.
E/E - 3K3 KP Zone 1
Access - 5K6 KP Zone 2
EOL - 2K2