beautypg.com

Warning, Programming sequence, Producer – MVVS 45 IFS User Manual

Page 2: Led blinking indication

background image

- connect servo to servo connector.

- keep clear of the propeller,
- power up ignition.

- move throttle stick until choke valve is completely closed,
- after aprox. 5 sec without move, LED blink and choke will move its position

to centre (PWM 1.5 ms) and after while it will return back.

- move throttle stick until choke valve is completely open,
- after cca 5 sec without move, LED blink and choke will move its position

to close and after while it will return back to open and close position.

a) SHORT SILENCER SETUP
- don’t move (at least 5 sec) the throttle stick (choke valve will still stay in open po-

sition), means the preignition curve for a short silencer is automatically installed,
LED is blinking in short intervals.

b) LONG SILENCER SETUP
- move the choke valve in closed position and wait at least 5 sec. Preignition curve

for a long silencer is installed, LED is blinking in long intervals.

- power off ignition,
- power off receiver, unplug programming cable, return throttle servo to receiver,
- connect enclosed LED to the ignition (red or red/black wire to left).

- power up ignition,
- the rest is described in Starting sequence on previous page.
Programming is necessary after first setting or when changing the preignition curve
or type of silencer. It’s not required to program the ignition before every start.
If the “easy – start” function is not required the ignition programming is not necessa-
ry, the default setting is preignition curve for “short” silencer.

WARNING!

– Use the ignition only in dry conditions,
– use recommended number and type of cells for every ignition type,
– the product is specified for RC engines only (other use must be approved by the

manufacturer),

– do not take off the resister cover if the ignition is on,

– danger of electric injury (voltage over 20 000 V),
– recharge ignition battery only outside the model,
– because of possible interferences, ignition and battery should be placed

at least 25 cm from the receiver!

DON‘T USE high power servo (or digital).

The manufacturer is not responsible for damages caused by not following the manual and misuse the ignition other than in RC engines!
You will lost your guarantee if you damage the high voltage (HV) cable or HV isolation, pickup, reverse the batteries or open ignition box!

Ignition needs to learn both positions of choke and type of silencer.

- firstly prepare ignition for programming (plug servo, plug programming cable to

receiver, power up receiver, power up transmitter, power up ignition,

- secondly set close position of choke,
- thirdly set open position of choke,

- fourthly chose type of silencer,
- finally power off ignition, unplug programming cable and return throttle servo

to receiver.

Type

Problem

Solution

- fast blinking

(after power up)

battery test is

running

Wait a while.

- fast blinking

(5sec after power up)

battery volta-

ge is low

Charge battery. Voltage is lower than 6,5V

(for S version) or 9,5V (for P version).

- one short flash per

second

sleep mode

spark is

blocked

Unplug battery and reconnect it again.

NORMAL OPERATION:

PROGRAMMING SEQUENCE:

LAST STEP:

FIRST STEP:

PRODUCER:

SECOND STEP:

THIRD STEP:

FOURTH STEP:

FIFTH STEP:

SIXTH STEP:

Air flow

Choke

Air flow

Choke

Air flow

Choke

Air flow

Choke

MSR Engines s.r.o.
Nálepkova 97
637 00 Brno / Czech
fax.: +420 545 210 903
e-mail: [email protected]

www.msrengines.eu

- connect ignition to receiver (throttle channel) with enclosed cable,
- connect battery to receiver,
- switch on transmitter,
- set throttle to the centre.

LED BLINKING INDICATION

ICU-S-ICU-P 2_0 EN.indd 2

4.10.2011 20:28:04