Manual Override Operation Instructions

Push hand wheel down.

1.

Rotate to align slot with flats.

2.

Push down a second time to disengage gear train.

3.

Rotate hand wheel clockwise to go to open or counter-clockwise to go to close.

4.

Note: Actuator does not have mechanical stops. Do no rotate past open or close position. Use visual indicator to po-
sition actuator.

Cross section drawings for ER4-15 Series Nema Type 7

Enclosure for Class I Groups C & D, Class II Groups E, F & G Div. 1 & 2 with de-clutching manual override

Depending on actuator size and enclosure, manual over ride and visual indicator may be optional equipment that
must be specified at time of order.

Hand Wheel

Visual Indicator

Slot

Steel Balls

Stem

Spring