Operation, Pre-lighting warnings, Operating test – MCZ Forma Wood 115 User Manual
Page 38: Attention

INSTALLATION AND USE MANUAL
Chapter 6
page
38
Operation
Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
6. OPERATION
6.1. PRE-LIGHTING WARNINGS
Do not touch the fireplace stove when it is lit for the first
time. During this phase, the paint finishes drying and
hardens. If you touch the paint, you may expose the steel
surface.
It is good practice to provide plenty of ventilation in the
room during the initial lighting, as the stove will give off a
small amount of smoke and smell of paint.
If necessary, touch up the paint with the aerosol spray in
the original colour (see “Fireplace stove accessories and
inserts")
Do not stay near the fireplace stove, and as previously mentioned,
ventilate the room. The smoke and the smell of paint will vanish after
about one hour of operation. There are no health risks involved.
The fireplace stove will be subject to expansion and contraction during
the stages of lighting and cooling down, and may therefore make slight
creaking noises.
This phenomenon is absolutely normal, the structure being made of
sheet steel, and must not be considered a fault.
It is very important not to bring the stove up to full
heat immediately. Bring it up to temperature
gradually.
This avoids damages to welds and the steel
structure.
Do
not
demand
full
heating
performance straight away!
6.2. OPERATING TEST
ATTENTION!!
BEFORE PROCEEDING IN ANY WAY WITH THE
INSTALLATION OF THE CLADDING, CARRY OUT A
GENERAL TEST OF THE FIREPLACE STOVE AS
FOLLOWS:
Raise and lower the fire door 7-8 times to ensure
fluid sliding and that the counterweights do not
produce noise when they come into contact with
the structure (if this anomaly occurs, review chapter
7.1.4)
Check that all of the wiring and the control unit (if
the kit COMFORT AIR VF is installed) are always
placed at a distance from the hot body of the
fireplace stove.
Test the ventilation kit at all speeds and in all
modes (if kit COMFORT AIR VF is installed)
Light the fire at low power to ensure the smoke
connections do not leak smoke or soot. Before
lighting, however, read Chapter 6.