Burner and nozzle specifications, Rr tc s s a – Hotpoint Ariston PKLL 751 T/IX/HA EE User Manual
Page 13
![background image](https://www.manualsdir.com/files/856550/content/doc013.png)
GB
13
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
100
75
55
130
0.80
0.45
0.45
1.65
2.70
1.75
1.05
3.50
39
28
28
61
80
64
50
65x2
196
127
76
254
193
125
75
250
2.70
1.75
1.05
3.50
122(H3)
96(Z)
79(6)
103x2
257
167
100
333
Burner and nozzle specifications
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m³
RR
TC
S
S
A
PKLL 751 T/IX/HA EE
This manual is related to the following products: