beautypg.com

Equator WB 818 User Manual

Page 13

background image

Defective seal on plunger.

Over filling container.

Replace plunger.

Follow instructions in owner’s

manual.

Noisy pump assembly.

Impellers not properly shimmed or

rubbing.

Pump parts not properly installed.

Debris in bottom of tub sump area.

Defective motor bearings.

Use shim gauge furnished in

impeller and seal kit, when seals

are properly shimmed the

impellers will be in correct

operating position.

Inspect and correct.

Clean out sump area.

Replace motor.

Dishwasher continues to fill

or continues to fill even

though in case of there is no

voltage to fill valve.

Something (dirt or foreign

material) under diaphragm in water

inlet valve.

Defective water inlet fill valve.

Clean water inlet valve or

replace.

Replace water inlet valve.

Detergent left in dispenser.

Detergent cup held or blocked by

large dishes.

Dispenser wet when detergent

was added.

On proper loading dishes.

Instructs customer/user.

Softener leaking

Softener broken.

Softener nut loosen.

Replace softener.

Screw down softener cap.

Leaking form air inlet.

Air inlet nut loose.

Air inlet install up side down.

Screw down air inlet nut.

Reinstall air inlet properly.

Window Display “E1”

Inlet Valve Damaged.

Inlet Valve Disconnected.

Replace Inlet Valve.

Reconnected Line.

Window Display “E2”

Pressure Switch Damaged.

Replace Pressure Switch.

Window Display “E3”

Heating Element (open).

Power Supply To heating Element

Cutting.

Replace.

Reconnect Line.

Window Display “E4”

Float Switch Act.

Take Remove The Rubber Cap

Let Water Pour Out.

Window Display “E5”

Thermostat Sensor Damaged.

Replace sensor(See figure8).

13