Equator WB 818 User Manual
Page 13
●Defective seal on plunger.
●Over filling container.
◇Replace plunger.
◇ Follow instructions in owner’s
manual.
Noisy pump assembly.
●Impellers not properly shimmed or
rubbing.
●Pump parts not properly installed.
●Debris in bottom of tub sump area.
●Defective motor bearings.
◇ Use shim gauge furnished in
impeller and seal kit, when seals
are properly shimmed the
impellers will be in correct
operating position.
◇Inspect and correct.
◇Clean out sump area.
◇Replace motor.
Dishwasher continues to fill
or continues to fill even
though in case of there is no
voltage to fill valve.
● Something (dirt or foreign
material) under diaphragm in water
inlet valve.
●Defective water inlet fill valve.
◇ Clean water inlet valve or
replace.
◇Replace water inlet valve.
Detergent left in dispenser.
●Detergent cup held or blocked by
large dishes.
● Dispenser wet when detergent
was added.
◇On proper loading dishes.
◇Instructs customer/user.
Softener leaking
●Softener broken.
●Softener nut loosen.
◇Replace softener.
◇Screw down softener cap.
Leaking form air inlet.
●Air inlet nut loose.
●Air inlet install up side down.
◇Screw down air inlet nut.
◇Reinstall air inlet properly.
Window Display “E1”
●Inlet Valve Damaged.
●Inlet Valve Disconnected.
◇Replace Inlet Valve.
◇Reconnected Line.
Window Display “E2”
●Pressure Switch Damaged.
◇Replace Pressure Switch.
Window Display “E3”
●Heating Element (open).
●Power Supply To heating Element
Cutting.
◇Replace.
◇Reconnect Line.
Window Display “E4”
●Float Switch Act.
◇Take Remove The Rubber Cap
Let Water Pour Out.
Window Display “E5”
●Thermostat Sensor Damaged.
◇Replace sensor(See figure8).
13