beautypg.com

Installation, Installing the appliance, Safe use of the appliance – Electrolux MC1761E User Manual

Page 31

background image

29

Installation

INSTALLING THE APPLIANCE

1. Remove all packaging and check carefully for any

signs of damage.

2. This oven is designed to fit into a 360mm high

cupboard as standard.
When fitting into a 350mm high cupboard:-
Unscrew and remove the 4 feet from the bottom of
the oven. There are 3 tall feet and 1 short foot.
Replace the 3 tall feet with those provided in the
accessory pack. Do not replace the short foot.

3. If fitting the microwave oven above a conventional

oven (position A) then use the mylar sheet provided.
a. Cut the Mylar sheet to

fit the internal
width of the
unit.

b. Peel back the

protective
cover on the
tape and fix
to the rear of
the shelf so
that it covers
the service gap.
(See diagram).

4. Fit the appliance into the kitchen cupboard slowly,

and without force, until the front frame of the oven
seals against the front opening of the cupboard.

5. Ensure the appliance is

stable and not leaning.
Ensure that a 5mm gap is
kept between the cupboard
door above and the top of
the frame (see diagram).

6. Fix the oven in position with the

screws provided.
The fixing points are located on
the top and bottom corners of
the oven (see diagram, item 9,
on page 4).

7. It is important to ensure that the installation of this

product conforms to the instructions in this
operation manual and the hob or conventional oven
manufacturer’s installation instructions.

5 mm

Mylar sheet

Conventional

oven

Internal width

Service gap

If fitting the microwave in position B or C:

• The cupboard must be a minimum of

500mm (E) above the worktop & must not
be installed directly above a hob.

• This appliance has been tested and

approved for use near domestic gas,
electric and induction hobs only.

• Sufficient space between hob and

microwave should be allowed to prevent
overheating of microwave oven,
surrounding cupboard and accessories.

• Do not operate the hob without pans

when the microwave oven is operating.

• Care should be taken when attending to

the microwave oven while the hob is on.

SAFE USE OF THE APPLIANCE

E

D

Position A

Position B

Position C

Position D

Conventional

oven

POSITION

NICHE SIZE

CHIMNEY

Gap Between

W

D

H

(min)

Cupboard & Ceiling

A

560 x 550 x 360

50

50

B + C

460 x 300 x 350

18

50

460 x 300 x 360

18

50

560 x 300 x 350

18

50

560 x 300 x 360

18

50

D

460 x 500 x 350

40

50

460 x 500 x 360

40

50

560 x 500 x 350

40

50

560 x 500 x 360

40

50

Measurements in (mm)

Chimney

Chimney

1. AG-21+22D-UK English 20/05/2004 12:30 Page 29