a
Hold Rail against wall and start
screws with washers.
b
Tighten screws with 13mm socket
head (power tool is recommended)
in the following sequence: 1st-lower
right; 2nd-upper left; 3rd-lower left;
4th-upper right.
DO NOT OVERTIGHTEN SCREWS!
For solid concrete applications, torque
screws to 60 in-lbs (6.8 N m).
Screws must be fully seated in order to
support applied load!
The minimum torque for screws in
solid wood studs is 60 in-lbs minimum
(6.8 N m)while the maximum torque is
82 in-lbs (9.3 N m).