Installing your cooker – Electrolux EKM11340KN User Manual
Page 24
Installing Your Cooker
The information below is crucial to installing this appliance
correctly and safely.
Where standards have been revised - always use the most
recent edition.
Failure to install appliances correctly is dangerous
and could lead to prosecution.
Ventilation Requirements
The room containing the appliance should have an air
supply in accordance with BS 5440:Part 2.
●
All rooms require an openable window, or equivalent,
and some will require a permanent vent as well.
●
For room volumes up to 5m3 an air vent of 100cm3 is
required.
●
For room volumes between 5m3 and 10m3 and air vent
of 50cm2 is required.
●
If the room has a door which opens directly to the
outside, or exceeds 10m3 - no air vent is required.
●
If there are other fuel burning appliances in the same
room, BS 5440:Part 2 should be consulted to determine
the air vent requirements.
●
This appliance must not be fitted into a bed sitting room
of less than 20m3 or into a bath or shower room.
Windows and vents should not be blocked or removed
without first consulting a competent engineer.
LPG only - do not install this appliance below ground
level. This does not preclude installation into rooms which
are basements with respect to one side of the building, but
open to ground level on the opposite side
.
21