beautypg.com

Operating instructions – Enviro EP3 User Manual

Page 8

background image

Auger Trim

Auger Trim

Auger Trim

2 Seconds

"ON"

3 Seconds

"ON"

Factory Setting

4 Seconds

"ON"

8

AUGER TRIM

FAN

MANUAL FEED

ON/OFF

HEAT LEVEL

3. AUGER PULSE LIGHT: This light will flash in

conjunction with the auger.

4. MANUAL AUGER FEED: If the unit runs out

of fuel, this button can be used to “prime the

auger system”. This button will turn off after 60

seconds and then must be released and pressed

again.

5. SYSTEM LIGHT: Responsible for signaling

the state of the control board. When the light

is flashing during start-up, the stove is in an

automatic start mode. When the light is solid,

the Heat Level Setting can be altered.

6. ON/OFF BUTTON: Used to turn the unit ON

and OFF.

7. HEAT OUTPUT INDICATOR: Shows the

present heat output setting.

8. HEAT LEVEL ADJUSTMENT: When pressed,

will change the heat setting of the unit from low

to high.

Operating Instructions

S

TOVE

C

ONTROLS

- C

IRCUIT

B

OARD

:

1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger

Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the

feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the burning of poor

quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On

time to 2 second. This setting is for high-grade fuel only. Push the button until just the number 1

light is on, this is for a three (3) second on time (standard setting).

2. CONVECTION BLOWER CONTROL: Used to turn the convection blower ON/OFF. If the Blower

is left off, and the sensor located on the air jacket reaches 160 °F (71 °C), the Convection blower

will automatically come on HI speed to cool the unit. Leave the convection blower ON for peak

efficiency

Figure 4: Circuit board control panel.

Figure 5: Auger trim and heat level indicator.