Error indication and its information – Escali E15CB User Manual

Page 11

background image

■ Procedures to set up time to automatically turn off the power

-

Push the “C” key for 5 seconds while the weight, quantity, unit weight of the scale are zero state and Tare is released as the picture No. 1.

W eighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g
(0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.01 lb)

lb

Model : CB-15N

WEIGHT

UNIT WEIGHT

QUANTITY

BAT

Short
Unit Wt.

TOTAL

TARE

ZERO

Short
Q'ty

kg

g/pc

pcs

-

Set up the preferable time to turn off the power by using the “+” key or “=” key while the display is showing as picture No. 2.

W eighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g
(0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.01 lb)

lb

Model : CB-15N

WEIGHT

UNIT WEIGHT

QUANTITY

BAT

Short
Unit Wt.

TOTAL

TARE

ZERO

Short
Q'ty

kg

g/pc

pcs

-

Complete the procedures to set up the time using the “M” key. Not pushing the “M” key does not save this function.

z

The scale is automatically turned off when not being used for selected time without inputting a key or changing the weight.

z

Used in order to prevent unnecessary consumption of the battery.

z

Select time to automatically turn off the power as OFF – 5min.- 10min. – 30min. – 60min. – 120min.

z

Release the time setup by setting up with ‘OFF’.

z

Without inputting a key for 5 seconds will automatically set back to the scale mode in the picture No. 2.

z

The scale is dispatched with ‘5 minutes automatic turning off the power’ mode. (The scale is automatically turned off when not being used for 5 minutes.)


7. Error Indication and its Information

Error Information

Solution

Error

Information

Solution

Err-01

Memory reading error

A/S

Err-02

Zero range error (Test mode)

A/S

Err-03

Problems in Weighing range (Test mode)

A/S

Err-d0

Exceed maximum weight

Check the platform, A/S

Err-d1

Below minimum weight

Check the platform

Err-d2

Problems in AD converter

A/S

Err-d3

Tare range error: Unstable condition, Exceed
tare range, Setting up the Tare during “-
(minus)“ weighing

Check the scale

Err-d4

Exceed maximum data range of AD
converter

Check to see if there is anything
on the platform, A/S

Err-d5

Below minimum data range of AD converter

Check the platform, A/S

Err-d6

Weighing range error

A/S

Err-d7

Problems in Zero / Exceed the range

A/S

Err-d8

Not in a stabilized condition

The

scale

is

experiencing

vibrations or wind currents : Place
the scale in a stabilized condition

- When the scale stops operating or ON/OFF key does not operate

- Reset the battery or adapter jack. When they do not operate after resetting the battery or adapter jack, claim the after service.