beautypg.com

Optional controllers – Empire Comfort Systems PV-28SV55-CN User Manual

Page 42

background image

22618-17-0308

Page 42

OPTIONAL CONTROLLERS

See your Mantis dealer for correct controller type.

MODELS

FRBTP

Battery Operated Remote w/ Programmable Thermostat

FRBTC

Battery Operated Remote w/ Thermostat

TRW

Battery Operated Wireless Remote Wall Thermostat

TMV2

Thermostat, 2 Stage

INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION

Installation Instructions for FRBTP, FRBTC, and TRW
The Remote Control FRBTP, FRBTC and TRW are all battery operated devices, which require a small amount of low voltage wiring.

Begin installation by unplugging the unit and removing the front louver panel.
Remove blue jumper wire from junction block and save for future use. Using wire provided in the Mantis Owner’s Manual Package,

connect remote wires using below schematic.
Black or white wire can be inserted in either remote control receiver connection hole. There is no polarity at this connection.

Figure 49

Replace front louver panel and plug unit into outlet. Turn both burner switches to the ON position. Burner switches must remain in the

ON position for remote to function. Set remote from the instructions provided with the remote control.

Note: When the heater or the Remote Control will not be used for long periods the burner switches should be in the OFF position, also

in summer the heater should be turned off at the power point.

Installation Instruction for TMV2 - Two Stage Thermostat Model:
Begin installation by unplugging the unit and removing the front louver panel.
Determine mounting location of thermostat. Using standard 18 AWG wire, run four (4) strands of wire into rear of Mantis

(See Figure 50) to junction block. Cut wire to correct length. Remove blue jumper wire from junction block and save for future use.

Connect four (4) new thermostat wires to Mantis using schematic. See Figure 51.

Figure 50

REMOTE

CONTROL

RECEIVER

BLACK

BLACK

WHITE

WHITE

RED

JUNCTION
BLOCK

TO

TRANSFORMER

BLUE

TO “T2” (REAR BURNER)

TO “T1” (FRONT BURNER)

WHITE

JUMPER WIRE
(TO BE REMOVED)

BLUE

W1 R

W2

C

BLUE

TO “T1”

TO “T2”