beautypg.com

Introduction & specifications, Operation – Sealey WPP2300 User Manual

Page 2

background image

2. INTRODUCTION & SPECIFICATIONS

A range of pond pumps suitable for creating garden water features such as fountains and waterfalls. They also provide the important

functions of filtration and water circulation which are necessary to maintain healthy plant and fish life. Each pump is supplied with 5

fountain heads (Fig.3) and 10m of cable.

3. OPERATION

WARNING! Ensure that you read, understand and apply the safety instructions in Section 1.

3.1. Start-up.

3.1.1. Place the pump on a flat level surface which is raised from the bottom of the pond. This prevents the pump from clogging too quickly.

3.1.2. You may use the pump lying on its side. You should however, make sure that the motor axis is horizontal, otherwise the shaft will be subject

to increased wear.

3.2.

Cascade Fountain Mode.

3.2.1. When installing the pump in the pond, make sure that the fountain head projects above the water surface. Please refer to

Fig.1 and ensure the regulating valve Fig.1.1 is set at o° (turned all the way to the right). The delivery heights and diameters in Fig.1

correspond to a condition in which the fountain head is placed 50mm above the water surface.

Technical Data.

Model:

WPP2300 WPP2650 WPP3500

Power Consumption:

55W

75W

95W

Max. Head:

2.3mtr

2.7mtr

3.0mtr

Max. Flow Rate:

2300ltr/h

2650ltr/h

3500ltr/h

Max. Submersion Depth:

2.3mtr

2.7mtr

3.0mtr

Power Cable:

10mtr

10mtr

10mtr

Max. Temp. of the Pumped Fluid:

35°C

35°C

35°C

Input:

230V 230V 230V

Protection Type:

IP68

IP68

IP68

Fig.1

1

2

Refer to Fig 1.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WPP2300 . . . . . . . WPP2650. . . . . . WPP3500

Diameter of 1st stage “C” . . . . . . . . . . . . . . . . . . . . . . . 1100mm . . . . . . . . 1200mm. . . . . . . 1320mm

Diameter of 2nd stage “B” . . . . . . . . . . . . . . . . . . . . . . . . 800mm . . . . . . . . 1000mm. . . . . . . 1100mm

Delivery head of 1st stage “D”. . . . . . . . . . . . . . . . . . . . . 700mm . . . . . . . . . 900mm. . . . . . . . 990mm

Delivery of second stage “E” . . . . . . . . . . . . . . . . . . . . . 1100mm . . . . . . . . 1450mm. . . . . . . 1595mm

Max. delivery head “F”. . . . . . . . . . . . . . . . . . . . . . . . . . 1300mm . . . . . . . . 1800mm. . . . . . . 1980mm

Distance from pump outlet to fountain head “G”. . . . . 240-395mm . . . . . 255-410mm. . . . .255-410mm

Distance from pump base to fountain head “H” . . . . 365-520mm . . . . . 380-535mm. . . . .380-535mm

3.3.

Fountain Heads.

3.3.1. A selection of fountain heads are supplied with the pump (fig.3). Choose the desired style and install onto the outlet pipe.

3.4.

Fountain and Water Spout Connection.

3.4.1. Additional water spectacles can be connected to the water spout connection (Fig.1.2) with a hose of 19mm OD.

3.4.2. To open the spout connection, turn the regulating valve (Fig.1.1) anticlockwise between 0-90° to adjust the flow between

the spout and the fountain head.

3.5.

Water Spout Only.

3.5.1. Turn the regulating valve all the way anticlockwise to 90°. All the water flow will now be through the water spout.

Fig.2

Original Language Version

WPP2300, WP2650, WPP3500 Issue: 5(S) - 17/09/14

© Jack Sealey Limited

This manual is related to the following products: