2. INTRODUCTION & SPECIFICATIONS

3. OPERATING INSTRUCTIONS

WARNING! Ensure you read, understand and apply safety instructions.

3.1. Fit appropriate discharge pipe to pump outlet and secure with clip. Ensure the diameter of the discharge pipe is the same as, or

greater than, the outlet diameter. A smaller pipe will adversely effect the pump flow rate.

3.2.

Position pump in the water, and place the outlet pipe securely in the discharge receptacle or area. We recommend the pump is

submerged with its discharge outlet facing up to release any trapped air.

3.3.

Plug the pump into the electrical mains supply and switch on.

The pump will automatically turn on as the level of water rises (fig.1.A). As water level lowers, the float will automatically switch the

pump off as it reaches the minimum height (B). Float may be adjusted by shortening or lengthening the cable. The pump will switch on

if the water level is up to or above the maximum length of the float cable. To function correctly the float must move freely. Ensure the

float can do so and that the cable is not restricted. Check that the pump and discharge are working correctly.

3.4.

The water into which the pump is placed will act as the motor cooling agent. For this reason the pump must remain submerged at all

times. Should the pump have to be used in shallow water

DO NOT operate for more than 10 minutes. Failure to follow this rule will

damage the unit and will invalidate your warranty.

NOTE: See fig.2 to determine minimum clearance required if using pump in a restricted area i.e. well, etc.

fig.1

WPD235A.V2

WPS225A.V2

fig.2

Manufactured from corrosion resistant materials with - stainless steel motor case and Noryl base cover - WPD235A.V2

- stainless steel body and motor case

- WPS225A.V2

Fitted with automatic cut-out. Designed for operation in dense and dirty water. Suitable for the effective drainage of cellars, sinks, cisterns,

baths and the general transfer of water and dense liquids.

Model No.

Cut-Out Outlet OD Maximum

Maximum Motor Input Maximum Minimum Maximum

Output

Head

Particle Size Water Depth Water Depth

WPD235A.V2 Automatic

38mm

217ltr/min

8mtr

750W 230V 35mm 40mm 7mtr

WPS225A.V2 Automatic

38mm

225ltr/min

7.5mtr

750W 230V 15mm 30mm 5mtr

Original Language Version

WPD235A.V2, WPS225A.V2 Issue: 1 - 14/12/12

© Jack Sealey Limited