beautypg.com

Recommended fuse rating: 3 amp, Charging instructions – Sealey POWERSTART200 User Manual

Page 2

background image

3.3.

ELECTRICAL SAFETY IN RELATION TO BATTERY CHARGERS

WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any

other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.

A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current

Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an

RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.

You must also read and understand the following instructions concerning electrical safety.

3.3.1. The

Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified

electrician, using a Portable Appliance Tester (PAT), at least once a year.

3.3.2. The

Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances

and the safety of the appliance operators.

If in any doubt about electrical safety, contact a qualified electrician.

3.3.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.

and use a Portable Appliance Tester.

3.3.4. Ensure that cables are always protected against short circuit and overload.

3.3.5. Regularly inspect power supply cables and plugs for wear or damage and check all connections

to ensure that none are loose.

3.3.6.

Important: Ensure that the voltage marked on the appliance matches the power supply to be

used and that the plug is fitted with the correct fuse - see fuse rating at right.

3.3.7.

DO NOT pull or carry the appliance by the power cable.

3.3.8.

DO NOT pull the plug from the socket by the cable.

3.3.9.

DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty

item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK

3 pin plug is damaged, cut the cable just above the plug and

dispose of the plug safely.

Fit a new plug according to the following instructions (UK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all wires have been correctly

connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.

Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.

To rewire, connect these two wires as indicated above -

DO NOT connect either wire to the earth terminal.

RECOMMENDED

FUSE RATING: 3 AMP

Blue

Neutral

Wire

Yellow & Green

Earth Wire

Cable

Restraint

Brown

Live

Wire

4. CHARGING INSTRUCTIONS

WARNING! YOU MUST FOLLOW THE SAFETY INSTRUCTIONS

IMPORTANT WARRANTY INFORMATION:

The battery pack fitted to this cordless tool is considered to be a consumable item and its ability

to accept charge will reduce over time. We will warranty it against mechanical and electrical

defect for a period of one year - this does not cover fair wear and tear. If the battery is not prop

erly charged before first use, or regularly conditioned, its capacity will diminish. Under these

circumstances we will not replace the battery pack even if it is less than one year old.

IMPORTANT! Only recharge POWERSTARTS with the AC charger provided. The charger is

automatic and does not require the user to monitor the progress of the charge.

Furthermore, whenever the Powerstart is not in use it should be connected to the

charger, failure to do this will invalidate the warranty.

4.1.

Reading the power level indicators

The charge level of the POWERSTART200 and 350 can be seen at any time by pressing the

test button (fig.1.A) and noting the meter (fig.1.E) reading.

When the needle is in the green sector the unit is fully charged and is ready to be used.

The red sector indicates that immediate charging is required and the yellow sector indicates

that recharging is advisable.

4.1.1. For the POWERSTART500 and 900 models press and hold the test button, the LED's (fig.2.E)

from left to right, four orange (low power) and six green will light up one by one and stop at the

level of charge, the further to the right the higher the charge.

POWERSTART200

fig.1

fig.2

A

B

C

D

POWERSTART900

E

F

If the unit receives a sharp knock or blow, it must be checked by a qualified service agent before being used.

DO NOT smoke or allow a spark or flame in the vicinity of the battery, engine or Powerstart.

DO NOT drop any metal tool onto the battery as it may produce a spark or short circuit, which could cause an explosion.

DO NOT use the unit to recharge dry cell batteries (commonly used in home appliances). These batteries may burst and cause injury to

persons and/or damage to property.

DO NOT charge or boost a frozen battery.

DO NOT allow the power lead clamps to touch each other, or to contact the same piece of metal, as this will result in a damaging short circuit.

DO NOT pull or carry the unit by its cables or wires and do not pull the negative and positive clamps from the battery terminals.

DO NOT operate in vicinity of flammable liquids or gases.

DO NOT recharge the unit with plugs, cables or attachments that are damaged. Replace such items immediately.

DO NOT use this product to perform a task for which it is not designed.

DO NOT store the unit in damp or wet locations or where temperature may exceed 50

o

C.

DO NOT submerge the unit in water.

DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.

DO NOT leave the unit in a totally discharged state for an extended period of time as this will result in permanent damage.

DO NOT cross-connect the power leads from the Powerstart to the battery. Ensure that positive is to positive and negative is to negative.

The Powerstarts may be used under any weather conditions - rain, snow, hot or cold.

Original Language Version

POWERSTART200 / 350 / 500.V2 / 900 Issue: 6(SP) - 25/09/13

© Jack Sealey Limited

This manual is related to the following products: