Technical specifications, Uninterruptible power system (ups) – Eaton Electrical Powerware 9825 User Manual

Page 4

background image

UPS Rating (0.9 power factor)
kVA

225 275 550

kW

202 250 500

General Characteristics
Efficiency

Up to 95%

Parallel Capability

Up to 3 modules, 550 kVA maximum

Audible Noise

< 65dBA @ 1 meter

Altitude (max)

2000m at 40ºC (104ºF)

N+1 Redundancy Capable Yes
Field Upgradeable

Yes, 275 kVA increments

System Bypass Module

Included

Input Characteristics
Voltage

480V standard; 208V and 600V with isolation

transformer option

Voltage Range

+10% / -15%

Frequency Range

55-65 Hz

Power Factor

0.99 (minimum)

Input Current Distortion

<3% (no input filter required)

Soft Start Capability

Yes

Internal Backfeed

Yes

Protection

Output Characteristics
Voltage

480V standard; 208V and 600V with isolation

transformer option

Regulation

±1%

Inverter

PWM with IGBT switching

Voltage THD

<2% (100% linear load); <5% (non-linear load)

Load Power Factor Range Up to a .9 power factor leading without de-rating

Battery
Battery Types

VRLA, AGM, Gel, Wet

Battery Voltage

480V

Temperature Compensation Optional
Charging Method

Advanced Battery Management technology

Dimensions & Weights
225 kVA, 275 kVA

52.4”w x 34.3”d x 73.7”h

1786 lb.

225 kVA redundant,

73.7”w x 34.3”d x 73.7”h

2875 lb.

275 kVA redundant
550 kVA

73.7”w x 34.3”d x 73.7”h

2977 lb.

550 kVA redundant

95.0”w x 34.3”d x 73.7”h

4153 lb.

Field upgrade module,

21.3”w x 34.3”d x 73.7”h

1176 lb

225 or 275 kVA

User Benefits
Control Panel (LCD)

8 lines x 40 characters

Battery Startup

Standard

Frequency Conversion

Standard

Remote Display Panel

Optional

Multi-language

Standard

Building Alarm Inputs

6 (galvanic isolated)

Serviceability
Back/Side Against Wall

Standard

Installation

Options
External Maintenance Bypass
Powerware PDU, RPP, and STS
Isolation Transformer
Output Transformer
Maintenance Bypass Module

Certifications
Safety

UL1778, cUL

EMC

FCC Class, A

Surge

ANSI C62, 41 Cat, A&B

eNotify Remote Monitoring
24x7 remote monitoring of 43 UPS and battery alarms, daily heartbeat check
and monthly report ConnectUPS Web/SNMP/xHub card

Communications
Software Compatibility - PowerVision

®

, LanSafe

®

,

FORESEER

®

, Power Xpert

Communication Cards - Standard system includes one ConnectUPS Web/SNMP card
with an Environmental Monitoring Probe. Four communication bays standard.
The following connectivity options can be installed at any time:
- ConnectUPS Web/SNMP/xHub
- Modus Card
- Relay Interface Card (Use for AS400s)
- Industrial Relay Card (5A@120V)
- Hot Sync CAN Bridge Card provides CAN communications, isolated RS-485 port
- Environmental Monitoring Probe (EMP)

3

Remote Inputs/Outputs - Six building alarms inputs and one summary alarm contact
(5A@120V) standard
Remote Panel - Eight backlit status indicator lamps plus an audible horn

3

Technical Specifications

2

© 2007 Eaton Corporation

All Rights Reserved

Printed in USA

9395FXA

March 2007

EUROPE/MIDDLE EAST/AFRICA

Denmark: 45.3686.7910

Finland: 358.94.52.661

France: 33.1.6012.7400

Germany: 49.7841.666.0

Italy: 39.02.66.04.05.40

Norway: 47.23.03.65.50

Sweden: 46.8.598.940.00

United Kingdom: 44.1753.608.700

ASIA PACIFIC

Australia/NZ: 61.2.9693.9366

China: 86.21.6361.5599

HK/Korea/Taiwan: 852.2745.6682

India: 91.11.2649.9414 to 18

Singapore/SEA: 65.6825.1668

Powerware, PowerVision, FORESEER, Power

Xpert, LanSafe, and ABM are trademarks of

Eaton Electrical Inc.

2. Due to continuing improvements, specifications are
subject to change without notice.

3. Requires the ConnectUPS Web/SNMP/xHub card.

Powerware® 9395-825 - Available Fall 2008

Uninterruptible Power System (UPS)

225 to 825 KVA

For additional information, please call 1-800-392-3299 or email [email protected] www.naat.com