Installation instructions and Owner’s Manual

5

Figure 3.

Ventilation from Outdoors

If necessary provide extra fresh air by using ventilation
grills or ducts. Connect these items directly to the
outdoors or spaces open to the outdoors. These
include attics* and crawl spaces. Follow the National
Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3, Air
for Combustion and Ventilation for required size of
ventilation grills or ducts.

*IMPORTANT: Do not provide openings for inlet or
outlet into attic. If attic has a thermostat-controlled
power vent, heated air entering the attic will activate
the power vent.

IMPORTANT: Vent-free heaters add moisture to the
air. Although this is beneficial, installing heater in
rooms without enough ventilation air may cause
mildew to form from too much moisture. See Fresh
Air for Combustion and Ventilation, pages 3 through
5.

INSTALLATION

NOTICE: This heater is intended for the use as supple-
mental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run system’s circulating blower while
using heater. This will help circulate the heat throughout
the house. In the event of a power outage, you can use
this heater as your primary heat source for the duration
of the outage.

WARNING: A qualified service person must install
heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural
gas
, do not install heater. Call dealer where you bought
heater for proper type heater.

THIS INSTALLATION REQUIRES:

Before installing heater, make sure you have the items
listed below:

Piping (check local codes)

Sealant (resistant to natural gas)

Equipment shutoff valve*

Ground joint union

Test gauge connection*

Sediment trap

Tee joint

Pipe wrench

*A CSA/AGA certified equipment shutoff valve with 1/8”
NPT tap is an acceptable alternative to test gauge
connection. Purchase a CSA/AGA certified equipment
shutoff valve from your dealer. See Accessories, page
17.

LOCATING HEATER

This heater is designed to be mounted on the wall. The
heater can also be located on a non-combustible floor,
away from a wall by using the floor mounting stands
included with the heater. If installed on combustible
flooring such as carpeting, tile or other combustible
material other than wood flooring, the heater must be
placed on a wood panel the full width and depth of the
appliance.

For convenience and efficiency, install the heater:

Where there is easy access for operation,
inspection, and service

In the coldest part of the room.

If planning to use fan, locate heater near an
electrical outlet.

CAUTION: If you install the heater in a home garage:
Heater pilot and burner must be at least 18 inches
above floor. Located heater where moving vehicle will
not hit it.

CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
covering or operating heater where impurities (such as
tobacco smoke, aromatic candles, cleaning fluids, oil or
kerosene lamps, etc.) are present in the air may
discolor walls.

WARNING: Never install the heater:

In a bathroom.

In a bedroom (IR20NGT, IR30NGT, BF20NGT
or BF30NGT)

In a recreational vehicle·.

Where curtains, furniture, clothing, or other
flammable objects are less than 36 inches from
the front, top, or sides of the heater.

As a fireplace insert

In high-traffic areas

In windy or drafty areas

WARNING: Heater must be mounted to maintain
the minimum clearances shown in Figure 4. If
possible, provide greater clearances from the floor,
ceiling, and joining walls.

INLET
AIR

OUTLET
AIR

VENTILATION CRAWL SPACE

TO CRAWL
SPACE

TO ATTIC

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345678

12345678

12

12

12

12

12

12

12

12

12

VENTILATION AIR

VENTILATED
ATTIC

12345

12345

OUTLET AIR