beautypg.com

User configuration menu (continued) configuration – Emerson 90 SERIES 1F95-391 User Manual

Page 7

background image

5

User Configuration Menu (Continued)

Configuration

7

(F)

C

Adjusts temperature display between F or C

TIME

FWD

8

SET FAN

(0)

0 HRS (OFF) to

6 HRS

Set Fan (one shot) option. Set the duration of the
one shot option.

TIME

FWD

9

BEEP

(ON)

OFF

Turns beeper ON or OFF.

TIME

FWD

10

HEAT FAST

(ON)

OFF

ON allows second stage to energize if setpoint is raised
3 or more degrees. OFF (economy) minimizes second
stage operation on setpoint changes.

TIME

FWD

11

COOL FAST

(OFF)

OFF

ON allows second stage to energize if setpoint is
lowered 3 or more degrees. OFF (economy) minimizes
second stage operation on setpoint changes.

TIME

FWD

12

Enables Remote Sensor A (connected to SA).

TIME

FWD

REMT SEN A

(OFF)

ON

13

Enables Remote Sensor B (connected to SA).

TIME

FWD

REMT SEN B

(OFF)

ON

14

Enables Remote Sensor C (connected to SA).

TIME

FWD

REMT SEN C

(OFF)

ON

15

STAT SEN L

(ON)

OFF

OFF Disables Thermostat Sensor. (Only available if
remote sensor A, B, or C is connected).

TIME

FWD

8

8

8

9&10

9

9&10

9&10

9&10

8