9
Overall dimensions
Width:
580 mm.
Depth:
500 mm.
Cut out dimensions
Width:
550 mm.
Depth:
470 mm.
Ignition HT Spark
Spark Generator
Ispra Control's BF 50066 -
230-240V 0.6 YA T 120
Spark Gap Fixed
Rear Left Burner (semi-rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input
3.0 kW (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
Rear Right Burner (semi-rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input
1.0 kW (3412 BTU/HR)
Supply connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
Instructions for the Installer
Engineers technical data
BURNER
RAPID
SEMI-RAPID
AUXILIARY
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
3.0
0.65
2.0
0.45
1.0
0.33
POWER (kW)
NOMINAL FLOW
0.286
0.062
0.190
0.043
0.095
0.031
RATE (m
3
/h)
NOZZLE REFERENCE
119
Adjust.
96
Adjust.
70
Adjust.
(1/100 mm)
NOMINAL THERMAL
2.8
0.65
2.0
0.45
1.0
0.33
POWER (kW)
NOMINAL FLOW
202
47
144
32
72
24
RATE (g/h)
NOZZLE REFERENCE
86
40
71
32
50
28
(1/100 mm)
NATURAL
GAS
20 mbar
TYPE OF
GAS
Characteristics
LPG GAS
28-30/37
mbar
VALUE
=
49.92
MJ/Kg
VALUE
=
37.78
MJ/m
3
Ws
-
50.7
MJ/
m
3
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
40
Aeration adjustment none
APPLIANCE CLASS:
3
APPLIANCE CATEGORY:
II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar